4.6 Article

Enhancing the accuracy of mid-infrared spectroscopy-based liver steatosis quantification using digital image analysis as a reference

期刊

ANALYST
卷 148, 期 13, 页码 3097-3106

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d3an00324h

关键词

-

向作者/读者索取更多资源

The assessment of liver steatosis is crucial in hepatology and liver transplantation surgery. Current methods for evaluating steatosis are time-consuming, subjective, and lack reproducibility. Recent research has shown that infrared spectroscopy could be used for real-time quantification of steatosis during abdominal surgery. This study developed and validated digital image analysis methods that provide accurate and reproducible reference values for steatosis quantification, enhancing the performance of infrared spectroscopic models. A PLS model in the 1810-1052 cm(-1) region using first derivative ATR-FTIR spectra provided RMSECV = 0.99%.
The assessment of liver steatosis is crucial in both hepatology and liver transplantation (LT) surgery. Steatosis can negatively impact the success of LT. Steatosis is a factor for excluding donated organs for LT, but the increasing demand for transplantable organs has led to the use of organs from marginal donors. The current standard for evaluating steatosis is a semi-quantitative grading based on the visual examination of a hematoxylin and eosin (H&E)-stained liver biopsy, but this method is time-consuming, subjective, and lacks reproducibility. Recent research has shown that infrared (IR) spectroscopy could be used as a real-time quantitative tool to assess steatosis during abdominal surgery. However, the development of IR-based methods has been hindered by the lack of appropriate quantitative reference values. In this study, we developed and validated digital image analysis methods for the quantitation of steatosis in H&E-stained liver sections using univariate and multivariate strategies including linear discriminant analysis (LDA), quadratic DA, logistic regression, partial least squares-DA (PLS-DA), and support vector machines. The analysis of 37 tissue samples with varying grades of steatosis demonstrates that digital image analysis provides accurate and reproducible reference values that improve the performance of IR spectroscopic models for steatosis quantification. A PLS model in the 1810-1052 cm(-1) region using first derivative ATR-FTIR spectra provided RMSECV = 0.99%. The gained improvement in accuracy critically enhances the applicability of Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) to support an objective graft evaluation at the operation room, which might be especially relevant in cases of marginal liver donors to avoid unnecessary graft explantation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据