4.5 Article

The DERIVO Embolization Device in the Treatment of Intracranial Aneurysms: Short- and Midterm Results

期刊

WORLD NEUROSURGERY
卷 95, 期 -, 页码 229-240

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.wneu.2016.07.101

关键词

Cerebral aneurysm; DERIVO endovascular device; Endovascular treatment; Flow diverter; Stent

向作者/读者索取更多资源

OBJECTIVE: The DERIVO embolization device (DED) is a new nitinol flow diverter stent manufactured for the treatment of intracranial aneurysms. In this study, we evaluated the safety and efficacy of the DED in the treatment of intracranial aneurysms and present the short- and midterm results. METHODS: We treated 34 aneurysms using 26 devices in 24 patients with wide-necked, mostly medium-sized, and fusiform aneurysms. Fourteen of the patients included in the study were women and the other 10 were men. Headache was the most frequent symptom. Although 31 (91.2%) aneurysms were in the anterior circulation, 3 (8.8%) were in the posterior. Intracranial stent medication was accomplished in all patients. All patients were evaluated 1 day later for any ischemic lesion with diffusion-weighted imaging. The first and second follow-up angiograms were planned to be performed after 3 and 9 months. RESULTS: In all patients, the treatment was successful. No hemorrhagic complication was seen on computed tomography scan performed immediately after the procedure. All patients were discharged without any neurologic deficit. Although 20 (71.4%) of 28 aneurysms in 20 patients were totally closed on the 3-month follow-up angiogram, 14 (77.8%) of 18 aneurysms in 9 patients were totally closed on the 9-month follow-up. General morbidity was 8.4%, and mortality was 4.3%. CONCLUSIONS: The DED seems effective and safe in the treatment of different kinds of intracranial aneurysms.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据