4.7 Article

Comparison between three preconcentration resins to determine dissolved gallium in natural waters using isotope dilution and high resolution inductively coupled plasma mass spectrometry

期刊

TALANTA
卷 265, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2023.124792

关键词

Natural water; Isotope dilution; Dissolved Ga; ICP-MS; Resin

向作者/读者索取更多资源

A new and accurate method was developed to determine the dissolved concentrations of Ga in natural waters. Chelex-100, Nobias Chelate PA-1, and Presep((R)) PolyChelate resins were compared for Ga extraction from river water and seawater. Presep((R)) PolyChelate resins were chosen for analysis due to their wide extraction range at low pHs. The optimal isotope dilution conditions for Ga concentration measurements in natural water were discussed.
A new and accurate method using resin enrichment of Ga, combined with isotope dilution, was developed to determine its dissolved concentrations in natural waters. The extraction properties of Chelex-100, Nobias Chelate PA-1, and Presep((R)) PolyChelate resins for Ga from river water and seawater were compared. Experiments were conducted to determine the optimal pH range, capacity to eliminate matrix and interference, extraction and elution times, and ideal quantity of resin beads. The Chelex-100 resins were determined to be inferior to the other resins in their ability to remove the matrix and interference. The properties of Nobias Chelate PA-1 and Presep((R)) PolyChelate were comparable, whereas Presep((R)) PolyChelate resins were ultimately chosen for sample analysis owing to their wide range for extracting Ga at low pHs compared to Nobias Chelate PA-1 resins. The optimal isotope dilution conditions for Ga concentration measurements in natural water are discussed. The procedural blank of the method was 0.42 & PLUSMN; 0.18 pmol/kg (N = 12, 1 SD) and the detection limit was 0.6 pmol/kg. Inter-calibration samples of GS were analyzed, with results of 41.6 & PLUSMN; 1.06 pmol/kg (N = 6, 1 SD), which agreed with previously reported data. Other intercalibration samples (GSP, GSC, NASS-6, NASS-7, SAFe D1, and SAFe D2) were also measured. The Ga, sampled using the contamination-free X-Vane method and conventional CTD rosette samplers, were compared and showed no statistical difference. Ga concentrations in different natural waters were determined. The Ga concentrations in rainwater were extremely low, whereas those in river water and seawater were in good agreement with existing knowledge.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据