4.3 Article

Simultaneous Determination of Vitamin E and & gamma;-Oryzanol in Rice Bran Oil via HPSEC-PDA without Sample Pretreatment

期刊

JOURNAL OF OLEO SCIENCE
卷 72, 期 7, 页码 655-665

出版社

JAPAN OIL CHEMISTS SOC
DOI: 10.5650/jos.ess22257

关键词

gamma-oryzanol; high-performance size exclusion chromatography; photodiode array detector; rice bran oil; vitamin E

向作者/读者索取更多资源

High-performance size exclusion chromatography (HPSEC) coupled with evaporative light scattering detector (ELSD) is utilized to separate and detect vitamin E and gamma-oryzanol in rice bran oil, without the need for sample pretreatment. The method provides accurate and reliable results.
Vitamin E (tocopherols and tocotrienols) and gamma-oryzanol are two minor constituents of rice bran oil (RBO) and are known to be potential bioactive compounds. The content of gamma-oryzanol, a unique antioxidant found only in RBO, is a key factor in determining the retail price of the oil. Limitations of conventional HPLC columns for vitamin E and gamma-oryzanol analysis are the alteration of these components and the time-consuming need for pretreatment of samples by saponification. High-performance size exclusion chromatography (HPSEC) equipped with a universal evaporative light scattering detector (ELSD) is a versatile tool for screening optimum mobile phase conditions because components of the sample can be separated and detected in the same run. In this work, the RBO components (triacylglycerol, tocopherols, tocotrienols, and gamma-oryzanol) assessed on a single 100-& ANGS; Phenogel column using ethyl acetate/isooctane/ acetic acid (30:70:0.1, v/v/v) as the mobile phase provided baseline separations (Rs >1.5) with a total run time of 20 min. The HPSEC condition was then transferred to determine the content of tocopherols, tocotrienols, and gamma-oryzanol in RBO products using a selective PDA detector. The limit of detection (LOD) and limit of quantification (LOQ) of alpha-tocopherol, alpha-tocotrienol, and gamma-oryzanol were 0.34 and 1.03 mu g/mL, 0.26 and 0.79 mu g/mL and 2.04 and 6.17 mu g/mL, respectively. This method was precise and accurate, with a percentage of relative standard deviation (%RSD) of the retention time of less than 0.21%. The intra-day and inter-day variations were 0.15-5.05% and 0.98-4.29% for vitamin E and gamma-oryzanol, respectively. The recoveries of tocopherols, tocotrienols, and gamma-oryzanol ranged between 90.75% and 107.98%. Thus, the developed HPSEC-ELSD-PDA method is a powerful analytical tool for determining the vitamin E and gamma-oryzanol present in oil samples without requiring any sample pretreatment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据