注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Clinical Neurology

Insertion Depth and Cochlear Implant Speech Recognition Outcomes: A Comparative Study of 28-and 31.5-mm Lateral Wall Arrays

Michael W. Canfarotta et al.

Summary: This study compared speech recognition outcomes between cochlear implant recipients with different lengths of lateral wall electrode arrays, finding that recipients of the 31.5-mm array had better performance at 12 months postactivation. Deeper insertion of the electrode array appears to improve speech recognition, with performance plateauing around 600 degrees.

OTOLOGY & NEUROTOLOGY (2022)

Article Otorhinolaryngology

Influence of electrode to cochlear duct length ratio on post-operative speech understanding outcomes

Shayna P. Cooperman et al.

Summary: The study suggests that the pre-operative electrode to cochlear duct length ratio is associated with post-operative speech recognition outcomes, but these outcomes cannot be solely predicted by electrode length.

COCHLEAR IMPLANTS INTERNATIONAL (2022)

Article Clinical Neurology

Impact of Cochlear Implant Array Placement on Speech Perception

Francesco Lo Russo et al.

Summary: The study assessed the role of flat panel CT in cochlear implant surgery and found that SID can predict the change in disyllabic score at 6-month follow-up, correlating with age at implantation and number of electrodes implanted.

CLINICAL NEURORADIOLOGY (2022)

Article Otorhinolaryngology

Is Cochlear Length Related to Congenital Sensorineural Hearing Loss: Preliminary Data

Mehmet Bilgin Eser et al.

Summary: The study found significant differences in the length of the cochlea between CSNHL patients and the control group, suggesting microanatomic dissimilarities in these two groups.

JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY (2021)

Article Medicine, Research & Experimental

Long-TermInfluence of Electrode Array Length on Speech Recognition in Cochlear Implant Users

Michael W. Canfarotta et al.

Summary: The study found that cochlear implant recipients with long lateral wall electrode arrays demonstrated superior speech recognition after 1 year and up to 4 years of listening experience. The benefit of longer arrays in improved speech recognition may be attributed to more widely spaced electrode contacts.

LARYNGOSCOPE (2021)

Article Audiology & Speech-Language Pathology

The Use of Clinically Measurable Cochlear Parameters in Cochlear Implant Surgery as Indicators for Size, Shape, and Orientation of the Scala Tympani

Daniel Schurzig et al.

Summary: The study assessed variations in human intracochlear anatomy and factors relevant to cochlear implantation, finding significant anatomical variability in the round window region. The study concluded that while there is generally enough space within the ST for CI, flexible surgical techniques and implant designs are important due to strong intracochlear anatomical variations. Cochlear dimensions, especially at the round window, could potentially indicate surgically challenging anatomies.

EAR AND HEARING (2021)

Article Engineering, Biomedical

An Approach for Individualized Cochlear Frequency Mapping Determined From 3D Synchrotron Radiation Phase-Contrast Imaging

Luke Helpard et al.

Summary: This study developed an individualized frequency mapping technique for cochlear implants by scanning cadaveric human cochleae and determining a personalized frequency function. The results showed significant reduction in pitch errors compared to the generalized approach, indicating the potential for revolutionizing cochlear implant programming worldwide.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2021)

Article Multidisciplinary Sciences

Three-dimensional tonotopic mapping of the human cochlea based on synchrotron radiation phase-contrast imaging

Hao Li et al.

Summary: This study conducted a three-dimensional frequency analysis of the human cochlea using dendritic mapping to accurately map the frequency in the basilar membrane/organ of Corti and the spiral ganglion. The findings have significant implications for validating electrode position and creating customized frequency maps for cochlear implant recipients.

SCIENTIFIC REPORTS (2021)

Article Audiology & Speech-Language Pathology

A MultiCenter Analysis of Factors Associated with Hearing Outcome for 2,735 Adults with Cochlear Implants

Benjamin Goudey et al.

Summary: This study investigates the association between 21 preoperative factors and speech recognition one year after cochlear implantation, providing evidence of 17 statistically significant associations. Despite the large sample size, the variance explained by the models remains modest. Additionally, a novel statistical interaction indicates that the duration of deafness in the implanted ear has a stronger impact on hearing outcome when considered relative to a candidate's age.

TRENDS IN HEARING (2021)

Review Medicine, Research & Experimental

Scalar Translocation Comparison Between Lateral Wall and Perimodiolar Cochlear Implant Arrays - A Meta-Analysis

Saad Jwair et al.

Summary: This study compared lateral wall and perimodiolar arrays in cochlear implantation and found that lateral wall arrays had significantly lower rates of scalar translocation and less negative impact on speech perception scores. Perimodiolar arrays were more prone to tip fold-over, indicating that lateral wall arrays may be the preferred option for minimizing intracochlear trauma in cochlear implantation.

LARYNGOSCOPE (2021)

Review Multidisciplinary Sciences

Cochlear implantation outcomes in adults: A scoping review

Isabelle Boisvert et al.

PLOS ONE (2020)

Article Clinical Neurology

Datalogging Statistics and Speech Recognition During the First Year of Use in Adult Cochlear Implant Recipients

Kara C. Schvartz-Leyzac et al.

OTOLOGY & NEUROTOLOGY (2019)

Article Medicine, Research & Experimental

Insertion Depth Impacts Speech Perception and Hearing Preservation for Lateral Wall Electrodes

Brendan P. O'Connell et al.

LARYNGOSCOPE (2017)

Article Clinical Neurology

Tip Fold-over in Cochlear Implantation: Case Series

M. Geraldine Zuniga et al.

OTOLOGY & NEUROTOLOGY (2017)

Review Otorhinolaryngology

Optimal electrode length to match patient specific cochlear anatomy

P. Mistrik et al.

EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES (2016)

Article Audiology & Speech-Language Pathology

The Influence of Cochlear Implant Electrode Position on Performance

Kim S. van der Marel et al.

AUDIOLOGY AND NEURO-OTOLOGY (2015)

Article Audiology & Speech-Language Pathology

Gradual adaptation to auditory frequency mismatch

Mario A. Svirsky et al.

HEARING RESEARCH (2015)

Article Clinical Neurology

Insertion Depth Angles of Cochlear Implant Arrays With Varying Length: A Temporal Bone Study

Annett Franke-Trieger et al.

OTOLOGY & NEUROTOLOGY (2014)

Article Clinical Neurology

Influence of Cochlear Implant Insertion Depth on Performance

Craig A. Buchman et al.

OTOLOGY & NEUROTOLOGY (2014)

Article Audiology & Speech-Language Pathology

Factors Affecting Auditory Performance of Postlinguistically Deaf Adults Using Cochlear Implants: An Update with 2251 Patients

Peter Blamey et al.

AUDIOLOGY AND NEURO-OTOLOGY (2013)

Article Otorhinolaryngology

Comparison of Cochlear Implant Performance after Round Window Electrode Insertion Compared with Traditional Cochleostomy

Bryan J. Kang et al.

OTOLARYNGOLOGY-HEAD AND NECK SURGERY (2013)

Article Neurosciences

A Model of Incomplete Adaptation to a Severely Shifted Frequency-to-Electrode Mapping by Cochlear Implant Users

Elad Sagi et al.

JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY (2010)

Article Clinical Neurology

Variational Anatomy of the Human Cochlea: Implications for Cochlear Implantation

Elsa Erixon et al.

OTOLOGY & NEUROTOLOGY (2009)

Article Clinical Neurology

Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes

Charles C. Finley et al.

OTOLOGY & NEUROTOLOGY (2008)

Article Neurosciences

Implications of deep electrode insertion on cochlear implant fitting

Mathieu Gani et al.

JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY (2007)

Article Acoustics

Frequency-place compression and expansion in cochlear implant listeners

D Baskent et al.

JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA (2004)

Article Audiology & Speech-Language Pathology

Effects of insertion depth of cochlear implant electrodes upon speech perception

K Yukawa et al.

AUDIOLOGY AND NEURO-OTOLOGY (2004)

Article Neurosciences

CT-derived estimation of cochlear morphology and electrode array position in relation to word recognition in nucleus-22 recipients

MW Skinner et al.

JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY (2002)