4.6 Article

Reactive Power Control of PV Inverters in Active Distribution Grids With High PV Penetration

期刊

IEEE ACCESS
卷 11, 期 -, 页码 81477-81496

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2023.3299351

关键词

Distribution network; photovoltaic; power loss minimization; smart inverters; Volt/VAR control

向作者/读者索取更多资源

A reactive power control approach for PV inverters is proposed to reduce the active power loss of the system and solve the overvoltage problem. The method uses probabilistic distributions to account for uncertainties in PV generation and load demand. The real-time volt/var control coordinates the operation of different inverters to limit voltage rise and reduce reactive power flow in the system. Simulation results show that the proposed controller is effective in reducing active power loss and solving the overvoltage problem with less reactive power requirement compared to other methods.
Photovoltaic (PV) systems can reduce greenhouse gas emissions while providing rapid reactive power support to the electric grid. At the distribution grid level, the PV inverters are controlled to reduce the system's active power loss and to address problems caused by the PV systems themselves. For example, the distribution grid may face overvoltages due to high PV generation during off-peak hours. In this paper, a reactive power control approach for PV inverters is proposed to control the injection/absorption of reactive power to reduce the active power loss of the system while solving the overvoltage problem. To achieve this, the proposed controller periodically dispatches the reactive power setpoints and applies a real-time volt/var algorithm. The proposed method uses probabilistic distributions to account for the uncertainties in PV generation and load demand. The controller is implemented at the lateral level which simplifies the required communication platform and reduces the computational cost. The real-time volt/var control coordinates the operation of the different inverters during overvoltage conditions so that the voltage rise is limited using as little reactive power as possible by the inverters. Accordingly, the active power loss due to reactive power flow in the system is reduced. Two distribution systems are simulated using Open Distribution System Simulator (OpenDSS) and used to evaluate the proposed controller and compare with two other methods. A daily time series simulation is performed to test different operating conditions. The simulation results show that the proposed controller is able to reduce the active power loss in general and solve the overvoltage problem with a lower reactive power requirement than the other volt/var methods.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据