Performance of the double-Wien filter of the Neoma MC-ICPMS/MS with an application to copper stable isotope compositions

期刊

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d3ja00182b

关键词

-

向作者/读者索取更多资源

The new Neoma MC-ICPMS/MS is equipped with a prefiltering system to improve its performance. The results show an asymmetrical attenuation of transmission, with higher efficiency at removing low masses than high masses. The asymmetry of the bandpass window can be predicted by theoretical calculations. The MS/MS technology of the Neoma allows for efficient on-line isolation of analytes and reduction of interferences.
The new Neoma MC-ICPMS/MS is equipped with a prefiltering system consisting of a double-Wien filter and a collision/reaction cell whose performances are challenged using different combinations of magnetic and electrostatic field values and adjustable slit apertures. The results show an asymmetrical attenuation of transmission relative to the chosen axial mass-to-charge value, with higher efficiency at removing low masses than high masses, even when magnetic induction is minimal. The resulting asymmetry of the bandpass window is fully predictable by theoretical calculations of ion trajectories in a Wien filter, either as a function of the magnetic field value or that of the aperture of the adjustable slit. With an axial mass-to-charge value set at Sn-120, the vertical deviation for a magnetic field value at 100% will be approximately 3 mm and 4 mm for a variation of mass-to-charge of & PLUSMN;20%, respectively. In these conditions, Ar was already barely detectable with the lowest magnetic field value (10%) and a fully open adjustable slit, while Pb is quantitatively transmitted. We then use the prefiltering system to remove on-line the (ArNa+)-Ar-40-Na-23 compound that produces an isobaric interference with Cu-63, hampering high-precision measurement of Cu stable isotope composition (Cu-65/Cu-63). While Na is not transmitted thanks to the double-Wien filter, (ArNa+)-Ar-40-Na-23 still interferes with Cu-63, demonstrating that this argide is produced in the plasma source but not in the reaction cell. Helium in the collision/reaction cell is necessary to remove the (ArNa+)-Ar-40-Na-23 interference. The MS/MS technology of the Neoma allows for the correction of the (ArNa+)-Ar-40-Na-23 interference up to a Na/Cu ratio of 10, where other classic MC-ICPMS already show an offset of the Cu stable isotope composition for a Na/Cu ratio of 1. The inability to correct the Cu stable isotope composition with a Na/Cu ratio higher than 10 suggests that the Na-based interference is no longer spectral and becomes linked to the matrix. We next measure the Cu stable isotope composition in eight certified reference materials prepared with a simple automated single step ion-chromatography procedure to purify Cu. The results show a very good agreement with previously reported values. The overall results suggest that the MS/MS technology of the Neoma MC-ICPMS allows efficient on-line isolation of analytes, therefore reducing potential spectral and matrix interferences to permit much better resolved and controlled subsequent effects in the collision/reaction cell.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据