4.6 Article

Effects of Geometric Parameters and Heat-Transfer Fluid Injection Direction on Enhanced Phase-Change Energy Storage in Vertical Shell-and-Tube System

期刊

SUSTAINABILITY
卷 15, 期 17, 页码 -

出版社

MDPI
DOI: 10.3390/su151713062

关键词

latent heat storage; phase-change materials; PCM melting; liquefaction rate; geometric parameters; HTF injection direction

向作者/读者索取更多资源

Internationally, energy-storage technologies have promoted the utilization of renewable energy and improved energy efficiency. This study focuses on the efficiency of vertical shell-and-tube energy-storage systems and investigates the influence of different heat-transfer fluid injection directions on phase-change materials melting in such systems, revealing that bottom HTF injection exhibits superior heat-transfer efficiency compared to top injection.
Internationally, energy-storage technologies have facilitated the large-scale utilization of renewable energy, reducing reliance on conventional power generation and enhancing energy efficiency. In the pursuit of strengthening the efficiency of phase-change energy-storage systems, the focus lies on further enhancing the efficiency of vertical shell-and-tube energy-storage systems. This study investigates the influence of two different heat-transfer fluid (HTF) injection directions on the melting of phase-change materials (PCM) in a vertical shell-and-tube latent heat storage (LHS) system. The melting behavior of PCM is analyzed under both pure conduction and natural convection conditions. The research findings reveal that during the initial melting stage, both HTF injection methods primarily rely on thermal conduction, resulting in no significant changes in PCM melting. However, in the later stages of natural convection, bottom HTF injection exhibits superior heat-transfer efficiency compared to top injection. Under a constant volume of phase-change material, both pipe length and pipe thickness affect the PCM melting process. As the pipe length increases within the range of 1.6 m to 0.2 m, the PCM melting time also increases. The results show that the melting time of the PCM is reduced by almost 15,000 s when the tube length H exceeds 800 mm, regardless of whether the heat-transfer fluid is injected at the top or bottom. In this paper, we also obtained results that the three composites containing 10% expanded graphite save 5.3%, 10.2%, and 14.3% of melting time, respectively, compared to pure paraffin when H = 200 mm and top injection are considered. For bottom injection, the three composites saved 7.7%, 12.5%, and 17.2% of melting time, respectively. This further emphasizes the more significant effect of priming in improving melting time.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据