4.5 Article

Assessing the dispersion of hydraulic conductivity values estimated using the Dupuit, Thiem, and Boulton methods on repeated pumping tests in an unconfined aquifer

期刊

HYDROGEOLOGY JOURNAL
卷 -, 期 -, 页码 -

出版社

SPRINGER
DOI: 10.1007/s10040-023-02665

关键词

Pumping/well test; Hydraulic conductivity; Variability; Aquifer properties

向作者/读者索取更多资源

This study compared the reproducibility of three methods (Dupuit, Thiem, and Boulton) for estimating hydraulic conductivity (K). The results showed that the Thiem method had the smallest dispersion, with half of the values falling within a range of ±11% of the average value. The Dupuit method provided average estimated K values that were close for both 2-hour and 5-day pumping tests, making it a good compromise between variability and site conditions.
Hydraulic conductivity (K) is rarely directly measured but can be estimated commonly through the Dupuit, Thiem, and Boulton methods. But which method can give more reproducible values? In this study, dispersion is assessed by examining the range of tolerance needed around the average value to get half of the values of a dataset available for a given borehole. A total of 403 values from 14 boreholes situated at a 1,150-m(2) test site in southwestern France were acquired from 2016 to 2020 using pumping tests of 2 h or 5 days. Estimated values of K ranged from 5.0 x 10(-6) to 9.6 x 10(-5) m/s. The Thiem method, usually providing a value between two boreholes, was modified to give an estimation for one borehole. This method presented the smallest dispersion: half of the values are within the interval of +11% of the average value, followed by the Boulton (+12%) and then Dupuit (+23%) methods. The Thiem and Dupuit methods can be used after a 2 h pumping in pseudo-steady-state condition; in contrast, the Boulton method requires long-term pumping. The Thiem method appeared dependent on the borehole quality, especially when considering the effect of clogging during short-term pumping. Finally, using the Dupuit method, average estimated K values from 2 h or 5-day pumping tests are close (3.1 x 10(-5) and 2.0 x 10(-5 )m/s, respectively). The Dupuit method was a good compromise between variability of the estimation and sensibility to site conditions. Also, measurements made with automated probes presented significant variability meaning that human error is not the sole factor of variability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据