4.5 Article

Influence of blinded wound closure on the volume stability of different GBR materials: an in vitro cone-beam computed tomographic examination

期刊

CLINICAL ORAL IMPLANTS RESEARCH
卷 27, 期 2, 页码 258-265

出版社

WILEY
DOI: 10.1111/clr.12590

关键词

alveolar ridge augmentation; block; bone; bone substitute; cone-beam computed tomography; dental implants; graft; guided bone regeneration; guided tissue regeneration; in vitro; membrane; pin; tack

资金

  1. Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Switzerland

向作者/读者索取更多资源

ObjectiveTo test whether the use of (i) particulated bone substitute + collagen membrane used for guided bone regeneration (GBR) of peri-implant bone defects renders different results from (ii) particulated bone substitute + collagen membrane + fixation pins and from (iii) block bone substitute + collagen membrane with respect to the volume stability of the augmented region during suturing of mucosal flaps. Material and methodsTwenty peri-implant box-shaped bone defects were created in 10 pig mandibles. Every bone defect was augmented once with each of the following GBR procedures: Granulate (particulated xenograft + collagen membrane), Granulate + Pins (particulated xenograft + collagen membrane + fixation pins), and Block (block xenograft + collagen membrane). Cone-beam computed tomography scans were obtained prior and after blinded wound closure. The horizontal thickness (HT) of the augmented region (bone substitute + membrane) was assessed at the implant shoulder (HT0mm) and at 1-5mm apical to the implant shoulder (HT1mm-HT5mm). The changes of HT during flap suturing were calculated as absolute (mm) and relative values (%). Repeated-measures ANOVA was used for statistical analysis. ResultsWound closure induced a statistically significant change of HT0mm and of HT1mm in all the treatment groups (P0.05). The change in HT0mm measured -42.817.9% (SD) for Granulate, -22.9 +/- 21.2% (SD) for Granulate + Pins, and -20.2 +/- 18.9% (SD) for Block. The reduction in HT0mm, HT1mm, HT2mm, and HT3mm for the Granulate procedure was significantly higher as compared to the Granulate + Pins and the Block procedures (P0.05). There were no statistically significant differences in the change of HT between the Granulate + Pins and the Block procedures (P>0.05). ConclusionWound closure induced displacement of the bone substitute resulting in a partial collapse of the collagen membrane in the coronal portion of the augmented site. The stability of the bone substitute and collagen membrane was enhanced by the application of fixation pins and by the use of block bone substitute instead of particulated bone substitute.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据