Free phenytoin assessment in patients: measured versus calculated blood serum levels

期刊

INTERNATIONAL JOURNAL OF CLINICAL PHARMACY
卷 38, 期 2, 页码 303-309

出版社

SPRINGER
DOI: 10.1007/s11096-015-0241-x

关键词

Phenytoin; Serum concentrations; Sheiner-Tozer equation; Therapeutic Drug Monitoring (TDM)

向作者/读者索取更多资源

Background Total serum drug levels are routinely determined for the therapeutic drug monitoring of selected, difficult-to-dose drugs. For some of these drugs, however, knowledge of the free fraction is necessary to adapt correct dosing. Phenytoin, with its non-linear pharmacokinetics, > 90 % albumin binding and slow elimination rate, is such a drug requiring individualization in patients, especially if rapid intravenous loading and subsequent dose adaptation is needed. In a prior long-term investigation, we showed the excellent performance of pharmacy-assisted Bayesian forecasting support for optimal dosing in hospitalized patients treated with phenytoin. In a subgroup analysis, we evaluated the suitability of the Sheiner-Tozer algorithm to calculate the free phenytoin fraction in hypoalbuminemic patients. Objective To test the usefulness of the Sheiner-Tozer algorithm for the correct estimation of the free phenytoin concentrations in hospitalized patients. Setting A Swiss tertiary care hospital. Method Free phenytoin plasma concentration was calculated from total phenytoin concentration in hypoalbuminemic patients and compared with the measured free phenytoin. The patients were separated into a low (35 a parts per thousand currency sign albumin a parts per thousand yen 25 g/L) and a very low group (albumin < 25 g/L) for comparing and statistically analyzing the calculated and the measured free phenytoin concentration. Main outcome measures Calculated and the measured free phenytoin concentration. Results The calculated (1.2 mg/L (SD = 0.7) and the measured (1.1 mg/L (SD = 0.5) free phenytoin concentration correlated. The mean difference in the low and the very low albumin group was: 0.10 mg/L (SD = 1.4) (n = 11) and 0.13 mg/L (SD = 0.24) (n = 12), respectively. Although the variability of the data could be a bias, no statistically significant difference between the groups was found: t test (p = 0.78), the Passing-Bablok regression, the Spearman's rank correlation coefficient of r = 0.907 and p = 0.00. The Bland-Altman plot including the regression analysis revealed no systematic differences between the calculated and the measured value [M = 0.11 (SD = 0.28)]. Conclusion In absence of a free phenytoin plasma concentration measurement also in hypoalbuminemic patients, the Sheiner-Tozer algorithm represents a useful tool to assist therapeutic monitoring to calculate or control free phenytoin by using total phenytoin and the albumin concentration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据