期刊
THIN-WALLED STRUCTURES
卷 107, 期 -, 页码 564-579出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.tws.2016.07.001
关键词
Built-up closed; Cold-formed steel; Column; Fire; Restraining; Buckling
资金
- Portuguese Foundation for Science and Technology - FCT [PTDC/ECM/116859/2010]
- PERFISA S.A. [PTDC/ECM/116859/2010]
- Fundação para a Ciência e a Tecnologia [PTDC/ECM/116859/2010] Funding Source: FCT
An experimental research on the fire behaviour of compressed cold-formed steel columns with closed built-up cross-sections and restrained thermal elongation is presented. Several parameters were assessed, including the influence of loading level, boundary conditions, restraint to thermal elongation imposed by the surrounding structure and cross-sectional shape. The investigation suggests that an increase in the non-dimensional axial restraint ratio and column load levels lead to a decrease in critical temperatures. Furthermore, the 350 degrees C critical temperature limit predicted in the EN 1993-1-3:2005 may be too simplistic and conservative for fire design of this type of columns. (C) 2016 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐