4.5 Article

Heparin-coated cardiopulmonary bypass circuits selectively deplete the pattern recognition molecule ficolin-2 of the lectin complement pathway in vivo

期刊

CLINICAL AND EXPERIMENTAL IMMUNOLOGY
卷 179, 期 2, 页码 294-299

出版社

WILEY
DOI: 10.1111/cei.12446

关键词

biocompatibility; cardiopulmonary bypass circuits; complement system; ficolin-2; lectin pathway

资金

  1. Svend Andersen Research Foundation
  2. Danish Medical Research Council
  3. Novo Nordisk Research Foundation
  4. Research Foundation of The Capital Region of Denmark
  5. Research Foundation of The Capital Region of Rigshospitalet

向作者/读者索取更多资源

The complement system can be activated via the lectin pathway by the recognition molecules mannose-binding lectin (MBL) and the ficolins. Ficolin-2 exhibits binding against a broad range of ligands, including biomaterials in vitro, and low ficolin-2 levels are associated with increased risk of infections. Thus, we investigated the biocompatibility of the recognition molecules of the lectin pathway in two different types of cardiopulmonary bypass circuits. Bloods were drawn at five time-points before, during and postoperatively from 30 patients undergoing elective cardiac surgery. Patients were randomized into two groups using different coatings of cardiopulmonary bypass circuits, Phisio (R) (phosphorylcholine polymer coating) and Bioline (R) (albumin-heparin coating). Concentrations of MBL, ficolin-1, -2 and -3 and soluble C3a and terminal complement complex (TCC) in plasma samples were measured. Ficolin-3-mediated complement activation potential was evaluated with C4, C3 and TCC as output. There was no significant difference between the two circuit materials regarding MBL, ficolin-1 and -3. In the Bioline (R) group the ficolin-2 levels decreased significantly after initiation of surgery (P<00001) and remained reduced throughout the sampling period. This was not seen for Phisio (R)-coated circuits. Ficolin-3-mediated complement activation potential was reduced significantly in both groups after start of operation (P<00001), whereas soluble C3a and TCC in the samples were increased (P<00001). Ficolin-2 was depleted from plasma during cardiac surgery when using heparin-coated bypass circuits and did not reach baseline level 24h postoperation. These findings may have implications for the postoperative susceptibility to infections in patients undergoing extracorporeal circulation procedures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据