期刊
SOLAR ENERGY MATERIALS AND SOLAR CELLS
卷 144, 期 -, 页码 109-116出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.solmat.2015.08.011
关键词
Solar salt; Molten salt corrosion; IN625; Stainless steels; Thermal energy storage; X20CrMoV11-1
资金
- Ferrostaal GmbH
The corrosion resistance of two ferritic steels P91 and X20CrMoV11-1, two austenitic steels SS316 and SS347H and a Ni-alloy IN625 is studied during long term isothermal immersion in molten nitrate salts consisting of 40% KNO3 and 60% NaNO3. The corrosion test was conducted at 600 degrees C for a maximum immersion time of 5000 h. The corrosion behavior was determined by recording the weight changes of samples at different time intervals and metallographic methods. The corrosion products were investigated in detail via electron probe micro-analysis (EPMA), and scanning electron microscopy (SEM). Results showed that P91 and X20CrMoV11-1 do not offer a sufficient long term corrosion resistance in molten nitrate salts. Stainless steels SS316 and SS347H instead formed protective oxide scales in both salts with similar kinetics. However, dissolution of the formed oxide scale in the form of alkali ferrite was observed on stainless steels. A linear weight loss with a very slow kinetics was evident for IN625. However, IN625 showed the best protective behavior among alloys. The qualitative and quantitative EPMA results revealed that a multiphase oxide layer composed of iron-chromium spinel, iron oxides, and sodium ferrite formed on the stainless steel SS347H. A dense NiO layer was primarily formed on the IN625 surface. (C) 2015 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐