4.6 Article

Thermal performance of a PCM-filled double-glazing unit with different thermophysical parameters of PCM

期刊

SOLAR ENERGY
卷 133, 期 -, 页码 207-220

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2016.03.039

关键词

Double-glazing unit; PCM; Thermophysical parameters

资金

  1. National Science Foundation of China (NSFC) [51306031]

向作者/读者索取更多资源

Application of phase change material (PCM) in the glazing structure can improve its thermal performance by enhancing its thermal energy storage capacity. In this study, the effect of thermophysical parameters of PCM on thermal performance of a PCM-filled double glazing unit was investigated. The results show that the temperature time lag of the PCM-filled double-glazing unit increases and the temperature decrement factor decreases with the increase of density, thermal conductivity, specific heat capacity, latent heat, and melting temperature of PCM. Increasing density, latent heat, and melting temperature of PCM are effective to enhance the thermal performance of PCM-filled double-glazed units; however, enhancing thermal conductivity and specific heat capacity are ineffective when thermal conductivity is beyond 2.1 W/(m K) and specific heat capacity is < 4460 J/(kg K). (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据