期刊
SOLAR ENERGY
卷 139, 期 -, 页码 744-756出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2015.09.034
关键词
PCM thermal storage; Effectiveness; Sensible energy; CSP
资金
- Australian Government, through the Australian Renewable Energy Agency (ARENA)
- Australian Solar Thermal Research Initiative (ASTRI) - Australian Government, through ARENA
The tube-in-tank is a compact configuration well suited for PCM thermal storage systems. However limited research has investigated the impact of the boundary condition applied to the PCM achieved through differing tube arrangements. In Part 1, using CFD and considering the discharging condition for CSP applications, it was determined that when the heat transfer fluid flow was in parallel, poor extraction of latent energy occurs, whereas in a counterflow arrangement maximum latent energy is extracted. In Part 2, the impact of mass flow rate and PCM thermal conductivity on the extraction of latent energy for these tube arrangements was investigated. It was discovered that the counterflow arrangement can experience poorer heat transfer which can be avoided through design. Furthermore, little investigation has considered the impact of the effectiveness of heat transfer with PCM systems with increased amounts of sensible energy, typical for CSP applications. It was determined that for latent dominant storage systems, the counterflow tube arrangement should be applied, while for sensible dominant PCM storage systems, parallel flow should be considered. (C) 2015 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐