4.7 Article

Study of PVDF asymmetric membranes in a high-throughput membrane bioreactor (HT-MBR): Influence of phase inversion parameters and filtration performance

期刊

SEPARATION AND PURIFICATION TECHNOLOGY
卷 162, 期 -, 页码 6-13

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.seppur.2016.02.008

关键词

HT-MBR; PVDF-membrane; Phase inversion; Membrane preparation; Membrane fouling; High throughput

资金

  1. KU Leuven [G.0808.10N]
  2. FWO [G.A.043.12N ERA-Net New INDIGO]
  3. OT [11/061]
  4. IOF-KP [IOFKP/13/004]
  5. Belgian Federal Government

向作者/读者索取更多资源

Porous polyvinylidene fluoride (PVDF) membranes with different morphology were prepared via phase inversion followed by comprehensive screening for use in activated sludge filtration applying new type of lab-scale high-throughput membrane reactor (HT-MBR). First, the validation of the HT-MBR was performed involving multiple filtration tests of PVDF membrane samples, either in the same or in different positions in the reactor to verify reproducibility of the measurements in the HT-MBR and to check the homogeneity of the feed liquor hydrodynamics in the reactor. The validated set-up was then used for an accelerated screening of a systematic set of membranes with varying structure. Sixteen PVDF-membranes with mean pore size ranging from 0.05 to 037 mu m and surface porosity from 2.8% to 13.9% were prepared via non-solvent induced phase separation by varying some phase-inversion parameters. The results showed that lowering the polymer concentration in the membrane casting solution, increasing the exposure time to the air of the cast membrane before solidification, and the use of additives (polyvinylpyrrolidone, PVP) to the casting solution resulted in more porous membranes, larger average pore sizes and higher surface porosities, thus offering higher clean water permeability. Activated sludge filtrations were evaluated implementing two different tests: a flux-stepping and a long-term filtration test. The more porous membranes were superior over the less porous ones, as higher critical fluxes and (slightly) higher permeance was maintained during the 37-day long-term test, although a sharp permeance decrease was observed in the first 7 days. However, for long-term application, these porous membranes should still be improved in order to have more sustained high permeability. (c) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据