4.7 Article

Experimental study on pipeline internal corrosion based on a new kind of electrical resistance sensor

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 224, 期 -, 页码 37-47

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2015.10.030

关键词

Ring pair sensor; Internal corrosion; On-line monitoring; Temperature difference; TLC

资金

  1. National Science & Technology Pillar Program of China [2011ZX05056]

向作者/读者索取更多资源

In this paper, a ring pair electrical resistance sensor (RPERS) has been developed for an internal-pipeline corrosion on-line monitoring system. The RPERS was divided into six segments along the circumference. The corrosion depth of each segment could be measured by using three alternating excitation currents injected into the sensor from different angles. In order to simulate and monitor the pipeline internal corrosion, a corrosion monitoring system which contained RPERS, wire electrical resistance sensor (WERS), thermocouples and a corrosion coupon was established. First, the corrosion processes in 3.5% sodium chloride solution with the temperature varied from 30 degrees C to 60 degrees C were studied. The temperature differences between the inner and outer pipe wall surfaces were measured by the top segment of RPERS. The test results revealed that the performance of RPERS is better than that of WERS in term of metal loss measurement. Then, carbon dioxide mixed with water vapour was pumped into the system with the temperature varied from 50 degrees C to 80 degrees C. In the scenarios, top of the line corrosion (TLC) occurred and was monitored by RPERS. The monitoring results demonstrated that the gas temperature and the temperature difference were important factors for TLC in sweet conditions. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据