4.5 Article

Atrioventricular Node Ablation in Langendorff-Perfused Porcine Hearts Using Carbon Ion Particle Therapy Methods and an In Vivo Feasibility Investigation for Catheter-Free Ablation of Cardiac Arrhythmias

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCEP.114.002436

关键词

atrial fibrillation; atrioventricular node; carbon particle therapy; catheter-free ablation; tachycardia, ventricular

资金

  1. German Heart Foundation (Mit Unterstutzung der Deutschen Herzstiftung e.V.)
  2. American Heart Association Midwest Affiliate Postdoctoral Fellowship Grant
  3. Helmholtz Association's Portfolio Topic Technology and Medicine
  4. Mayo Clinic Foundation
  5. Goldsmith Foundation

向作者/读者索取更多资源

Background-Particle therapy, with heavy ions such as carbon-12 (C-12), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned C-12 beam. Methods and Results-Intact hearts were explanted from 4 (30-40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomgraphic scans (1 mm voxel and slice spacing) were acquired and C-12 ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomgraphic scans for detection of beta(+) (C-11) activity were obtained. A C-12 beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomgraphy demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong gamma H2AX signals in the target region, whereas no gamma H2AX signals were detected in the unirradiated control heart. Conclusions-This is the first report of the application of a C-12 beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using C-12 beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据