4.8 Article

Infective Endocarditis After Transcatheter Aortic Valve Implantation Results From a Large Multicenter Registry

期刊

CIRCULATION
卷 131, 期 18, 页码 1566-1574

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.114.014089

关键词

endocarditis; heart valves; transcatheter aortic valve implantation

资金

  1. Instituto de Salud Carlos III, Madrid, Spain
  2. Red de Investigacion Cardiovascular, Instituto de Salud Carlos III, Spain
  3. CNPq, Conselho Nacional de Desenvolvimento Cientifico e Tecnologico-Brasil

向作者/读者索取更多资源

Background-We aimed to determine the incidence, predictors, clinical characteristics, management, and outcomes of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). Methods and Results-This multicenter registry included 53 patients (mean age, 79 +/- 8 years; men, 57%) who suffered IE after TAVI of 7944 patients after a mean follow-up of 1.1 +/- 1.2 years (incidence, 0.67%, 0.50% within the first year after TAVI). Mean time from TAVI was 6 months (interquartile range, 1-14 months). Orotracheal intubation (hazard ratio, 3.87; 95% confidence interval, 1.55-9.64; P=0.004) and the self-expandable CoreValve system (hazard ratio, 3.12; 95% confidence interval, 1.37-7.14; P=0.007) were associated with IE (multivariate analysis including 3067 patients with individual data). The most frequent causal microorganisms were coagulase-negative staphylococci (24%), followed by Staphylococcus aureus (21%) and enterococci (21%). Vegetations were present in 77% of patients (transcatheter valve leaflets, 39%; stent frame, 17%; mitral valve, 21%). At least 1 complication of IE occurred in 87% of patients (heart failure in 68%). However, only 11% of patients underwent valve intervention (valve explantation and valve-in-valve procedure in 4 and 2 patients, respectively). The mortality rate in hospital was 47.2% and increased to 66% at the 1-year follow-up. IE complications such as heart failure (P=0.037) and septic shock (P=0.002) were associated with increased in-hospital mortality. Conclusions-The incidence of IE at 1 year after TAVI was 0.50%, and the risk increased with the use of orotracheal intubation and a self-expandable valve system. Staphylococci and enterococci were the most common agents. Although most patients presented at least 1 complication of IE, valve intervention was performed in a minority of patients, and nearly half of the patients died during the hospitalization period.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据