4.2 Article

The MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013): ESTIMATION OF PLUTONIUM SKELETAL BURDEN FROM LIMITED AUTOPSY BONE SAMPLES FROM MAYAK PA WORKERS

期刊

RADIATION PROTECTION DOSIMETRY
卷 176, 期 1-2, 页码 117-131

出版社

OXFORD UNIV PRESS
DOI: 10.1093/rpd/ncw239

关键词

-

资金

  1. U.S. Department of Energy (U.S. DOE)
  2. Federal Medical Biological Agency (FMBA) of the Russian Federation

向作者/读者索取更多资源

The method to estimate total skeleton plutonium burden of former Mayak Production Association (MPA) workers from limited bone samples obtained at autopsy is described. From two to nine bone samples were obtained at autopsies conducted from the mid-1950s to 2013. Plutonium was measured using alpha-radiometry up to 2000 and later by alpha-spectrometry. The method was validated using data from whole-body donations from the United States Transuranium and Uranium Registries (USTUR). The developed algorithm overestimated the USTUR values from 20 to 40%, that is quite acceptable for conservative estimation. Late-in-life liver diseases known to redistribute plutonium between liver and skeleton were not associated with significant differences in plutonium deposition among sampled bones, except for the pelvis. Sources of uncertainties are discussed and future studies will address the reduction of these uncertainties. This algorithm can be used to obtain data in support of the development of biokinetic, dosimetric and risk models for humans exposed to plutonium.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据