4.7 Article

Electroremediation of PCB contaminated soil combined with iron nanoparticles: Effect of the soil type

期刊

CHEMOSPHERE
卷 131, 期 -, 页码 157-163

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.chemosphere.2015.03.007

关键词

Electroremediation; nZVI; Polychlorinated biphenyls PCB; Contaminated soil

资金

  1. European Regional Development Fund (ERDF) through COMPETE - Operational Programme for Competitiveness Factors (OPCF)
  2. Portuguese National funds through FCT - Fundacao para a Ciencia e a Tecnologia [PTDC/AGR-AAM/101643/2008 NanoDC]
  3. [FP7-PEOPLE-IRSES-2010-269289-ELECTROACROSS]
  4. [SFRH/BD/76070/2011]
  5. Fundação para a Ciência e a Tecnologia [PTDC/AGR-AAM/101643/2008, SFRH/BD/76070/2011] Funding Source: FCT

向作者/读者索取更多资源

Polychlorinated biphenyls (PCB) are carcinogenic and persistent organic pollutants that accumulate in soils and sediments. Currently, there is no cost-effective and sustainable remediation technology for these contaminants. In this work, a new combination of electrodialytic remediation and zero valent iron particles in a two-compartment cell is tested and compared to a more conventional combination of electrokinetic remediation and nZVI in a three-compartment cell. In the new two-compartment cell, the soil is suspended and stirred simultaneously with the addition of zero valent iron nanoparticles. Remediation experiments are made with two different historically PCB contaminated soils, which differ in both soil composition and contamination source. Soil 1 is a mix of soils with spills of transformer oils, while Soil 2 is a superficial soil from a decommissioned school where PCB were used as windows sealants. Saponin, a natural surfactant, was also tested to increase the PCB desorption from soils and enhance dechlorination. Remediation of Soil 1 (with highest pH, carbonate content, organic matter and PCB concentrations) obtained the maximum 83% and 60% PCB removal with the two-compartment and the three-compartment cell, respectively. The highest removal with Soil 2 were 58% and 45%, in the two-compartment and the three-compartment cell, respectively, in the experiments Without direct current. The pH of the soil suspension in the two-compartment treatment appears to be a determining factor for the PCB dechlorination, and this cell allowed a uniform distribution of the nanoparticles in the soil, while there was iron accumulation in the injection reservoir in the three-compartment cell.. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据