期刊
OPTICS EXPRESS
卷 24, 期 4, 页码 3615-3637出版社
OPTICAL SOC AMER
DOI: 10.1364/OE.24.003615
关键词
-
类别
资金
- BELSPO agency
- European Community's Seventh Framework Programme (FP7) [606797]
- GIGASSAT [ANR-12-AGRO-0001]
Monte Carlo simulations are used to compute the uncertainty associated to light backscattering measurements in turbid waters using the ECO-BB (WET Labs) and Hydroscat (HOBI Labs) scattering sensors. ECO-BB measurements provide an accurate estimate of the particulate volume scattering coefficient after correction for absorption along the short instrument pathlength. For Hydroscat measurements, because of a longer photon pathlength, both absorption and scattering effects must be corrected for. As the standard (sigma) correction potentially leads to large errors, an improved correction method is developed then validated using field inherent and apparent optical measurements carried out in turbid estuarine waters. Conclusions are also drawn to guide development of future short pathlength backscattering sensors for turbid waters. (C)2016 Optical Society of America
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据