期刊
OPTICS AND LASERS IN ENGINEERING
卷 86, 期 -, 页码 106-114出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.optlaseng.2016.05.016
关键词
Galvanometer; Vision system; Field distortion; Laser micromachining
类别
资金
- Deutscher Akademischer Austauschdienst (DAAD)
- German Research Foundation (DFG), Excellence Initiative by the German federal and state governments [F-003661-553-41A-1132104]
Laser galvanometer scanning systems are well-established devices for material processing, medical imaging and laser projection. Besides all the advantages of these devices like high resolution, repeatability and processing velocity, they are always affected by field distortions. Different pre-compensating techniques using iterative marking and measuring methods are applied in order to reduce such field distortions and increase in some extends the accuracy of the scanning systems. High-tech devices, temperature control systems and self-adjusting galvanometers are some expensive possibilities for reducing these deviations. This contribution presents a method for reducing field distortions using a coaxially coupled vision device and a self-designed calibration plate; this avoids, among others, the necessity of repetitive marking and measuring phases. (C) 2016 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐