4.1 Article

Make It Less Complex: Autoencoder for Speckle Noise Removal-Application to Breast and Lung Ultrasound

期刊

JOURNAL OF IMAGING
卷 9, 期 10, 页码 -

出版社

MDPI
DOI: 10.3390/jimaging9100217

关键词

Speckle noise; ultrasound; deep learning

向作者/读者索取更多资源

This study proposed a simplified Convolutional Neural Network Autoencoder (CNN-AE) to remove noise from breast and lung ultrasound images. The results showed that the model outperformed traditional filters in denoising. Furthermore, in the classification of malignant breast lesions, the use of the denoised images by the model reduced misclassifications. Therefore, this research is of great importance for practical clinical applications.
Ultrasound (US) imaging is used in the diagnosis and monitoring of COVID-19 and breast cancer. The presence of Speckle Noise (SN) is a downside to its usage since it decreases lesion conspicuity. Filters can be used to remove SN, but they involve time-consuming computation and parameter tuning. Several researchers have been developing complex Deep Learning (DL) models (150,000-500,000 parameters) for the removal of simulated added SN, without focusing on the real-world application of removing naturally occurring SN from original US images. Here, a simpler (<30,000 parameters) Convolutional Neural Network Autoencoder (CNN-AE) to remove SN from US images of the breast and lung is proposed. In order to do so, simulated SN was added to such US images, considering four different noise levels (sigma = 0.05, 0.1, 0.2, 0.5). The original US images (N = 1227, breast + lung) were given as targets, while the noised US images served as the input. The Structural Similarity Index Measure (SSIM) and Peak Signal-to-Noise Ratio (PSNR) were used to compare the output of the CNN-AE and of the Median and Lee filters with the original US images. The CNN-AE outperformed the use of these classic filters for every noise level. To see how well the model removed naturally occurring SN from the original US images and to test its real-world applicability, a CNN model that differentiates malignant from benign breast lesions was developed. Several inputs were used to train the model (original, CNN-AE denoised, filter denoised, and noised US images). The use of the original US images resulted in the highest Matthews Correlation Coefficient (MCC) and accuracy values, while for sensitivity and negative predicted values, the CNN-AE-denoised US images (for higher sigma values) achieved the best results. Our results demonstrate that the application of a simpler DL model for SN removal results in fewer misclassifications of malignant breast lesions in comparison to the use of original US images and the application of the Median filter. This shows that the use of a less-complex model and the focus on clinical practice applicability are relevant and should be considered in future studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据