4.7 Article

The effect of spatial resolution on decoding accuracy in fMRI multivariate pattern analysis

期刊

NEUROIMAGE
卷 132, 期 -, 页码 32-42

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2016.02.033

关键词

Multivariate pattern analysis; fMRI; 7 T; Spatial resolution; Spatial smoothing; Auditory cortex

资金

  1. Marie Curie Initial Training Network grant of EU [PITN-GA-2009-238593]
  2. VIDI grant of the Netherlands Organization for Scientific Research (NWO) [452-11-002]
  3. NWO VICI grant [453-12-002]

向作者/读者索取更多资源

Multivariate pattern analysis (MVPA) in fMRI has been used to extract information from distributed cortical activation patterns, which may go undetected in conventional univariate analysis. However, little is known about the physical and physiological underpinnings of MVPA in fMRI as well as about the effect of spatial smoothing on its performance. Several studies have addressed these issues, but their investigation was limited to the visual cortex at 3 T with conflicting results. Here, we used ultra-high field (7 T) fMRI to investigate the effect of spatial resolution and smoothing on decoding of speech content (vowels) and speaker identity from auditory cortical responses. To that end, we acquired high-resolution (1.1 mm isotropic) fMRI data and additionally reconstructed them at 2.2 and 3.3 mm in-plane spatial resolutions from the original k-space data. Furthermore, the data at each resolution were spatially smoothed with different 3D Gaussian kernel sizes (i.e. no smoothing or 1.1, 2.2, 3.3, 4.4, or 8.8 mm kernels). For all spatial resolutions and smoothing kernels, we demonstrate the feasibility of decoding speech content (vowel) and speaker identity at 7 T using support vector machine (SVM) MVPA. In addition, we found that high spatial frequencies are informative for vowel decoding and that the relative contribution of high and low spatial frequencies is different across the two decoding tasks. Moderate smoothing (up to 2.2 mm) improved the accuracies for both decoding of vowels and speakers, possibly due to reduction of noise (e.g. residual motion artifacts or instrument noise) while still preserving information at high spatial frequency. In summary, our results show that - even with the same stimuli and within the same brain areas-the optimal spatial resolution for MVPA in fMRI depends on the specific decoding task of interest. (C) 2016 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据