Predictive value of extubation failure by decrease in central venous oxygen saturation: A systematic review and meta-analysis

期刊

HELIYON
卷 9, 期 7, 页码 -

出版社

CELL PRESS
DOI: 10.1016/j.heliyon.2023.e18227

关键词

Ventilator weaning; Central venous oxygen saturation; Sensitivity; Specificity

向作者/读者索取更多资源

This study summarized the diagnostic value of extubation failure tested by ΔScvO2. A total of five studies including 353 patients were included, and the pooled analysis showed that ΔScvO2 performed well in predicting extubation failure. However, further studies with larger sample sizes and well-designed models are needed to confirm its diagnostic accuracy and utility in mechanical ventilation patients.
Background: The predictive power of extubation failure diagnosed by decrease in central venous oxygen saturation (& UDelta;ScvO2) varies by studies. Here we summarized the diagnostic value of extubation failure tested by & UDelta;ScvO2. Methods: A comprehensive online search was performed to select potentially eligible studies that evaluated the predictive power of extubation failure tested by & UDelta;ScvO2. A manual search was also performed to identify additional studies. Data were extracted to calculate the pooled sensitivity, specificity, positive likelihood ratio (LR), negative LR, diagnostic odds ratio (DOR), and area under the receiver operating characteristic curve (AUC) to evaluate the predictive power of extubation failure. Results: Overall, five studies including 353 patients were included in this review, of whom 105 (30%) were extubation failure. The cutoff values of & UDelta;ScvO2 varied across studies, ranging from 3.8% to 5.4%. Heterogeneity between studies was assessed with an overall Q = 0.007, I2 = 0%, and P = 0.498. The pooled sensitivity and specificity for the overall population were 0.83 (95% CI: 0.74-0.90) and 0.88 (95% CI: 0.83-0.92), respectively. The pooled positive LR and negative LR were 7.2 (95%CI: 4.6-11.2) and 0.19 (95%CI: 0.12-0.31), respectively. The DOR was 38 (95% CI: 17-86). Overall, the pooled AUROC was 0.92 (95% CI: 0.90-0.94). Conclusions: The & UDelta;ScvO2 performed well in predicting extubation failure in adult mechanical ventilation patients. Further studies with a larger data set and well-designed models are required to confirm the diagnostic accuracy and utility of ScvO2 in predicting extubation outcomes in mechanical ventilation patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据