4.5 Article

Efficacy of Infrared Vein Visualization versus Standard Technique for Peripheral Venous Cannulation in Infant and Toddler Populations: A Randomized Study

期刊

CHILDREN-BASEL
卷 10, 期 10, 页码 -

出版社

MDPI
DOI: 10.3390/children10101652

关键词

anesthesia; intravenous access; toddlers; infrared vein visualization

向作者/读者索取更多资源

This study compared the efficacy of infrared vein visualization to the standard cannulation technique for obtaining peripheral intravenous access in infants and toddlers. The results showed no significant difference between the two techniques in terms of first-attempt success rate and time to establish cannulation. However, in difficult access situations, the infrared vein visualization device proved to be a valuable adjunct.
Establishing intravenous (IV) access in younger patient populations via the traditional cannulation technique for procedures requiring anesthesia is often challenging. Infrared (IR) vein visualization is a modality that aids venous cannulation; however, few reports of this technique exist in the infant and toddler population. The primary aim of this study was to compare the efficacy of IR vein visualization to the standard cannulation technique for obtaining peripheral IV access in infant and toddler populations. Following Institutional Review Board (IRB) approval and written informed consent, children were randomly assigned to either a standard cannulation technique group or an IR vein visualization device group for venous cannulation. The primary outcome variable was the success rate of IV cannulation, and the secondary variables were the total number of attempts and the time to successful cannulation. No difference was noted between either group for first-attempt success rate (standard versus IR: 61.25% vs. 54.4%; p = 0.4) or time to establish IV cannulation (standard versus IR: median [interquartile range], 40 s [24-120] vs. 53 s [26-106]; p = 0.55). The anesthesiologist's grading of the anticipated difficulty of IV cannulation was a significant predictor of cannulation success (p = 0.0016). Our study demonstrated no significant benefit in utilizing the IR vein visualization device in terms of the overall success rate, number of attempts, and time to establish successful IV cannulation when compared to the standard technique. However, in difficult IV access situations, this device proved to be a valuable rescue adjunct.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据