4.7 Article

The Development and Evaluation of Reagentless Glucose Biosensors Using Dendritic Gold Nanostructures as a Promising Sensing Platform

期刊

BIOSENSORS-BASEL
卷 13, 期 7, 页码 -

出版社

MDPI
DOI: 10.3390/bios13070727

关键词

constant potential amperometry; ferrocenecarboxylic acid; glucose oxidase; gold nanostructures; graphite rod electrode; polymerization; phenanthroline-dione; tetramethylbenzidine; tetrathiafulvalene

向作者/读者索取更多资源

Reagentless electrochemical glucose biosensors were developed using graphite rod electrodes modified with dendritic gold nanostructures and redox mediators in combination with glucose oxidase. Among various combinations, the biosensor based on threefold-layer-by-layer-deposited phenathroline-5,6-dione (PD) and glucose oxidase was found to be the most suitable for glucose determination. The performance of the biosensor was further improved by modifying the electrode surface with polypyrrole, resulting in a wide linear dynamic range, high sensitivity, low limit of detection, and good repeatability.
Reagentless electrochemical glucose biosensors were developed and investigated. A graphite rod (GR) electrode modified with electrochemically synthesized dendritic gold nanostructures (DGNs) and redox mediators (Med) such as ferrocenecarboxylic acid (FCA), 1,10-phenathroline-5,6-dione (PD), N,N,N & PRIME;,N & PRIME;-tetramethylbenzidine (TMB) or tetrathiafulvalene (TTF) in combination with glucose oxidase (GOx) (GR/DGNs/FCA/GOx, GR/DGNs/PD/GOx, GR/DGNs/TMB/GOx, or GR/DGNs/TTF/GOx) were developed and electrochemically investigated. A biosensor based on threefold-layer-by-layer-deposited PD and GOx (GR/DGNs/(PD/GOx)(3)) was found to be the most suitable for the determination of glucose. To improve the performance of the developed biosensor, the surface of the GR/DGNs/(PD/GOx)(3) electrode was modified with polypyrrole (Ppy) for 5 h. A glucose biosensor based on a GR/DGNs/(PD/GOx)(3)/Ppy((5 h)) electrode was characterized using a wide linear dynamic range of up to 39.0 mmol L-1 of glucose, sensitivity of 3.03 & mu;A mM(-1) cm(-2), limit of detection of 0.683 mmol L-1, and repeatability of 9.03% for a 29.4 mmol L-1 glucose concentration. The Ppy-based glucose biosensor was characterized by a good storage stability (& tau;(1/2) = 9.0 days). Additionally, the performance of the developed biosensor in blood serum was investigated.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据