4.7 Article

A Facile Method for the Fabrication of the Microneedle Electrode and Its Application in the Enzymatic Determination of Glutamate

期刊

BIOSENSORS-BASEL
卷 13, 期 8, 页码 -

出版社

MDPI
DOI: 10.3390/bios13080828

关键词

microneedles; electrochemical biosensor; glutamate oxidase; neurotransmitters; glutamate

向作者/读者索取更多资源

In this study, a simple method was used to fabricate a microneedle electrode (MNE). A commercial self-dissolving microneedle patch was first used to create a mold, which was then filled with conductive platinum paste and cured. The Pt-MNE was characterized using CV, EIS, and SEM, and its electrochemical applicability was demonstrated by immobilizing glutamate oxidase enzyme to detect glutamate.
Herein, a simple method has been used in the fabrication of a microneedle electrode (MNE). To do this, firstly, a commercial self-dissolving microneedle patch has been used to make a hardpolydimethylsiloxane-based micro-pore mold (MPM). Then, the pores of the MPM were filled with the conductive platinum (Pt) paste and cured in an oven. Afterward, the MNE made of platinum (Pt-MNE) was characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). To prove the electrochemical applicability of the Pt-MNE, the glutamate oxidase enzyme was immobilized on the surface of the electrode, to detect glutamate, using the cyclic voltammetry (CV) and chronoamperometry (CA) methods. The obtained results demonstrated that the fabricated biosensor could detect a glutamate concentration in the range of 10-150 mu M. The limits of detection (LODs) (three standard deviations of the blank/slope) were also calculated to be 0.25 mu M and 0.41 mu M, using CV and CA, respectively. Furthermore, the Michaelis-Menten constant (KMapp) of the biosensor was calculated to be 296.48 mu M using a CA method. The proposed biosensor was finally applied, to detect the glutamate concentration in human serum samples. The presented method for the fabrication of the mold signifies a step further toward the fabrication of a microneedle electrode.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据