期刊
FRONTIERS IN CARDIOVASCULAR MEDICINE
卷 10, 期 -, 页码 -出版社
FRONTIERS MEDIA SA
DOI: 10.3389/fcvm.2023.1233694
关键词
atrial fibrillation; heart failure; His-Purkinje system pacing; His bundle pacing; left bundle branch pacing; meta-analysis
This meta-analysis evaluated the safety and efficacy of His-Purkinje system pacing (HPCSP) in individuals with atrial fibrillation (AF) complicated by heart failure (HF). The results showed that HPCSP improved cardiac function, reduced mortality and rehospitalization events, and had great clinical application value.
Aim: To evaluate the safety and efficacy of the His-Purkinje system pacing (HPCSP) in the treatment of individuals with atrial fibrillation (AF) complicated by heart failure (HF).Methods: The PubMed, Cochrane Library, Web of Science, and Embase databases were searched through September 1, 2022. The literature was initially screened based on the inclusion and exclusion criteria. The baseline characteristics of the subjects, implantation success rate, New York Heart Association (NYHA) classification, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDd), QRS duration, pacing threshold, and impedance were extracted and summarized; statistical analysis was performed using RevMan 5.3 software.Results: In all, 22 articles were included, involving 1,445 patients. Compared to biventricular pacing (BiVP), HPCSP resulted in improved cardiac function, including increased ejection fraction (MD = 5.69, 95% CI: 0.78-10.60, P = 0.02) and decreased LVEDd (MD = -3.50, 95% CI: -7.05-0.05, P = 0.05). It was also correlated with shorter QRS duration (MD = -38.30, 95% CI: -60.71--15.88, P < 0.01) and reduced all-cause mortality and rehospitalization events (RR = 0.72, 95% CI: 0.57-0.91, P < 0.01) in patients. Left bundle branch pacing (LBBP) lowered the pacing threshold (MD = 0.47; 95% CI: 0.25-0.69; P < 0.01), and there was no statistical difference in the rate of endpoint events when comparing these two physiologic pacing modalities (RR = 1.56, 95% CI: 0.87-2.80, P = 0.14).Conclusion: The safety and efficacy of HPCSP in patients with AF and HF were verified in this meta-analysis. HPCSP can reverse cardiac remodeling and has great clinical application value. Relatively speaking, His-bundle pacing (HBP) can maintain better ventricular electro-mechanical synchronization, and the pacing parameters of LBBP are more stable.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据