4.7 Article

Experimental study on seismic behavior of steel angle truss reinforced concrete columns under compression-bending-shear-torsion combined action

期刊

JOURNAL OF BUILDING ENGINEERING
卷 73, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jobe.2023.106626

关键词

Steel reinforced concrete; Compression -bending -shear -torsion; Seismic behavior; Angle steel truss; Quasi -static test

向作者/读者索取更多资源

This study discusses the seismic behavior of steel angle truss reinforced concrete (SARC) columns under compression-bending-shear-torsion combined action. Ten SARC columns were designed and tested, and the influence of various parameters on the seismic performance was investigated. The failure modes, hysteretic curves, and important performance parameters of the specimens were obtained. The study also proposed a calculation method for torsional bearing capacity of SARC columns under compression-bending-shear-torsion combined action.
This study discusses the seismic behavior of steel angle truss reinforced concrete (SARC) columns under compression-bending-shear-torsion combined action. Ten SARC columns were designed and tested to investigate the influence of the axial compression ratio, torsion-bending ratio, shear span ratio, volume ratio of steel plates, and cover thickness. The failure modes and hysteretic curves of specimens were obtained in the test. The important performance parameters of the specimens were compared to evaluate the seismic performance of the specimens, including bearing capacity, stiffness degradation, ductility, and energy dissipation. The results show that the failure modes of SARC columns could be classified as bending failure, bending-torsion failure, shear-torsion failure, and torsional failure depending on the torsion-bending ratio and shear span ratio. An obvious pinch effect can be observed in the middle of the T-& theta; hysteresis curves of specimens, but the P-& UDelta; hysteresis curves are full. The torsional capacity of SARC columns can be improved by adding the axial compression ratio, torsion-bending ratio, and volume ratio of steel plates, but the effect is adverse when increasing cover thickness and shear span ratio. Moreover, a calculation method of torsional bearing capacity of SARC columns under compression-bendingshear-torsion combined action was proposed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据