4.7 Article

Theoretical, numerical and experimental studies on thermal insulation performance of different cross laminated timber walls

期刊

JOURNAL OF BUILDING ENGINEERING
卷 72, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jobe.2023.106640

关键词

Cross-laminated timber; Heat transfer coefficient; Thermal insulation; Full-scale test

向作者/读者索取更多资源

This paper studied the thermal performance of CLT walls through experiments, theoretical formulas, and simulation. The heat transfer coefficient of CLT walls was measured, the influence of wall structure and thermal insulation materials was analyzed, and the heat transfer coefficient of different CLT walls was predicted. The results showed that the addition of thermal insulation materials significantly reduced the heat transfer coefficient of CLT walls.
Cross laminated timber (CLT) is recognized as alternative to traditional building materials, which is mainly used as wall or floor of buildings. The heat transfer coefficient of wall is an important indicator of building energy saving, but there are relatively few studies on it of CLT wall. This paper mainly studied on the thermal performance of CLT walls by experiments, theoretical formulae and simulation. Based on hot box-heat flux method, the heat transfer coefficient values of CLT walls were measured and the influence of wall structure and thermal insulation materials were analyzed. Then, the heat transfer coefficient of different CLT walls was predicted by theoretical calculation and theoretical methods were compared based on calculation results. Finally, the temperature distribution, heat flux distribution and heat transfer coefficient of CLT wall were simulated and the applicable climate regions of CLT wall were proposed. The results showed that the double-layer structure or hollow structure had little effect on the heat transfer coefficient of CLT wall. The heat transfer coefficient of CLT wall significantly reduced by 37%-50% after adding internal or external thermal insulation materials. The lowest heat transfer coefficient of CLT walls in this study was 0.278 W/(m2*K). The arithmetic mean relative error of composite method is lower than the parallel-path method and the isothermal planes method, which was 6.38%. And the arithmetic mean relative error of heat transfer coefficient between simulation and experiment results was 7.46%. Thermal bridge structures in buildings, such as corners and partitions, will bring about 35%-38% increasement in heat transfer coefficient. These findings should be able to provide scientific basis for the use of CLT buildings in different cold regions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据