Thermal energy storage (TES) is crucial for the operation of concentrated solar power (CSP) plants. A sensible heat storage system using confined bed of small particle size granular material was experimentally evaluated. The temperature distribution in the bed and the total pressure drop of the TES system were monitored, and the experimental results matched well with the analytical model, showing the proper confinement of the granular material.
Thermal energy storage (TES) is an essential subsystem for the uniform operation of concentrated solar power (CSP) plants. A sensible heat storage system based on a novel confined bed of small particle size granular ma-terial was experimentally evaluated. The bed of regular silica sand was mechanically confined between a bottom and a top perforated plate gas distributor, to prevent the motion of particles even for gas velocities above the minimum fluidization velocity of the solids, operating the bed under a fixed or packed bed regime. The discharge process of the confined bed was experimentally analyzed, preheating the granular material at 300-320 degrees C and supplying various volumetric flow rates of cold air through the bottom distributor. During the discharge process, the temperature of the bed was segregated, obtaining a high temperature zone at the top region and a low temperature zone at the bottom region of the bed. These regions are separated by a thermocline that evolves in the upwards direction as the discharge process progresses. The temperature distribution in the bed and the total pressure drop of the TES system were monitored during the tests. For all cases, the temperature of the bed at different heights evolves as in a fixed bed, confirming the proper confinement of the granular material. The thermocline velocity depends on the volumetric flow rate of cold air, obtaining a discharge time for the tem-perature located at the exit of the system of around 50, 40, and 30 min for air volumetric flow rates of 700, 900, and 1100 Nlpm, respectively, using 55 kg of regular silica sand as granular material. The experimental results of the evolution and distribution of temperature in the bed were compared with an analytical model of the process for a fixed/packed bed regime of operation, resulting in a good agreement between the experimental mea-surements and the numerical predictions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据