4.7 Article

Dynamic Monitoring of Intracellular Tacrolimus and Mycophenolic Acid Therapy in Renal Transplant Recipients Using Magnetic Bead Extraction Combined with LC-MS/MS

期刊

PHARMACEUTICS
卷 15, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/pharmaceutics15092318

关键词

renal transplant; tacrolimus; mycophenolic acid; peripheral blood mononuclear cell; LC-MS/MS

向作者/读者索取更多资源

The study developed a method to quantify the concentrations of Tacrolimus and Mycophenolic acid in peripheral blood mononuclear cells (PBMCs) using liquid chromatography tandem mass spectrometry. The concentrations were measured in renal transplant recipients and were found to have a weak correlation with whole blood concentrations. The proposed method provides clinically reliable information on drug concentration at an active site, but further research is needed to study its application in adverse outcomes of renal transplant.
Background: Tacrolimus (TAC) and mycophenolic acid (MPA) are commonly used immunosuppressive therapies after renal transplant. Our objective was to quantify TAC and MPA concentrations in peripheral blood mononuclear cells (PBMCs) using liquid chromatography tandem mass spectrometry (LC-MS/MS) and to evaluate and validate the performance of the methodology. A prospective follow-up cohort study was conducted to determine whether intracellular concentrations were associated with adverse outcomes in renal transplants. Methods: PBMCs were prepared using the Ficoll separation technique and purified with erythrocyte lysis. The cells were counted using Sysmex XN-3100 and then packaged and frozen according to a 50 mu L volume containing 1.0 x 10(6) cells. TAC and MPA were extracted using MagnaBeads and quantified using an LC-MS/MS platform. The chromatography was run on a reversed-phase Waters Acquity UPLC BEH C18 column (1.7 mu m, 50 mm x 2.1 mm) for gradient elution separation with a total run time of 4.5 min and a flow rate of 0.3 mL/min. Mobile phases A and B were water and methanol, respectively, each containing 2 mM ammonium acetate and 0.1% formic acid. Renal transplant recipients receiving TAC and MPA in combination were selected for clinical validation and divided into two groups: a stable group and an adverse outcome group. The concentrations were dynamically monitored at 5, 7, 14, and 21 days (D5, D7, D14, and D21) and 1, 2, 3, and 6 months (M1, M2, M3, and M6) after operation. Results: Method performance validation was performed according to Food and Drug Administration guidelines, showing high specificity and sensitivity. The TAC and MPA calibration curves were linear (r(2) = 0.9988 and r(2) = 0.9990, respectively). Both intra-day and inter-day imprecision and inaccuracy were less than 15%. Matrix effects and recoveries were satisfactory. The TAC and MPA concentrations in 304 real PBMC samples from 47 renal transplant recipients were within the calibration curve range (0.12 to 16.40 ng/mL and 0.20 to 4.72 ng/mL, respectively). There was a weak correlation between PBMC-C-0TAC and WB-C-0TAC (p < 0.05), but no correlation was found for MPA. The level of immunosuppressive intra-patient variation (IPV) was higher in PBMC at 77.47% (55.06, 97.76%) than in WB at 34.61% (21.90, 49.85%). During the dynamic change in C-0TAC, PBMC-C-0TAC was in a fluctuating state, and no stable period was found. PBMC-C-0TAC did not show a significant difference between the stable and adverse outcome group, but the level of the adverse outcome group was generally higher than that of the stable group. Conclusions: Compared with conventional therapeutic drug monitoring, the proposed rapid and sensitive method can provide more clinically reliable information on drug concentration at an active site, which has the potential to be applied to the clinical monitoring of intracellular immunosuppressive concentration in organ transplantation. However, the application of PBMC-C-0TAC in adverse outcomes of renal transplant should be studied further.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据