4.7 Article

Free-Hand MIS TLIF without 3D Navigation-How to Achieve Low Radiation Exposure for Both Surgeon and Patient

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Clinical Neurology

Patient radiation exposure from intraoperative computed tomography in spinal surgery

Jan-Helge Klingler et al.

Summary: Intraoperative CT imaging results in higher radiation exposure for patients compared to 3D C-arm, highlighting the need for proper system selection and dose-saving protocols.

SPINE JOURNAL (2022)

Article Clinical Neurology

Trends in Intraoperative Assessment of Spinal Alignment: A Survey of Spine Surgeons in the United States

David M. Gullotti et al.

Summary: This study surveyed spine surgeons in the US to analyze their practices and shortcomings in intraoperative spinal alignment assessments. The results showed that the majority of surgeons primarily rely on radiographs for intraoperative assessments, with a low utilization of navigation cameras. There is a high demand for improvement in technology for intraoperative spinal alignment assessments.

GLOBAL SPINE JOURNAL (2022)

Article Clinical Neurology

Radiation Exposure in Minimally Invasive Lumbar Fusion Surgery A Randomized Controlled Trial Comparing Conventional Fluoroscopy and 3D Fluoroscopy-based Navigation

Jan-Helge Klingler et al.

Summary: The study compared the radiation exposure of surgeons and patients using FLUORO and NAV intraoperative imaging techniques. The results showed that the average radiation exposure of surgeons was lower in the NAV group without statistical significance and the radiation exposure of the patient was significantly higher in the NAV group.
Article Clinical Neurology

Comparison of Minimally Invasive Versus Open Transforaminal Interbody Lumbar Fusion

Chi Heon Kim et al.

GLOBAL SPINE JOURNAL (2020)

Review Clinical Neurology

A meta-analysis comparing ALIF, PLIF, TLIF and LLIF

Ian Teng et al.

JOURNAL OF CLINICAL NEUROSCIENCE (2017)

Review Clinical Neurology

Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review

Ahmed A. Aoude et al.

EUROPEAN SPINE JOURNAL (2015)

Article

Minimally Invasive Technique for PMMA Augmentation of Fenestrated Screws

Jan-Helge Klingler et al.

TheScientificWorldJOURNAL (2015)

Article

Minimally Invasive Technique for PMMA Augmentation of Fenestrated Screws

Jan-Helge Klingler et al.

Scientific World Journal (2015)

Review Clinical Neurology

The accuracy of pedicle screw placement using intraoperative image guidance systems

Alexander Mason et al.

JOURNAL OF NEUROSURGERY-SPINE (2014)

Article Clinical Neurology

Worldwide Survey on the Use of Navigation in Spine Surgery

Roger Haertl et al.

WORLD NEUROSURGERY (2013)

Review Oncology

Cancer risks associated with external radiation from diagnostic imaging procedures

Martha S. Linet et al.

CA-A CANCER JOURNAL FOR CLINICIANS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Unprotected Operator Eye Lens Doses in Oncologic Interventional Radiology Are Clinically Significant: Estimation from Patient Kerma-area-product Data

Lawrence T. Dauer et al.

JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Eye lens exposure to radiation in interventional suites: Caution is warranted

Eliseo Vano et al.

RADIOLOGY (2008)

Article Public, Environmental & Occupational Health

Increased cancer risk among surgeons in an orthopaedic hospital

G Mastrangelo et al.

OCCUPATIONAL MEDICINE-OXFORD (2005)