The Validation of Two-Dimensional and Three-Dimensional Radiographic Measurements of Host Bone Coverage in Total Hip Arthroplasty for Hip Dysplasia: A Comparison with Intra-Operative Measurements

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Orthopedics

Acetabular cup fixation with and without screws following primary total hip arthroplasty: migration evaluated by radiostereometric analysis

Jennifer S. Polus et al.

Summary: The use of screws for cup fixation in total hip arthroplasty was found to have a significant effect on cup migration. Cups fixed with only 1 screw showed greater migration compared to those with no screws or 2 screws, although the mean magnitude was still below the threshold for unacceptable migration.

HIP INTERNATIONAL (2023)

Article Health Care Sciences & Services

A Comprehensive Research on the Prevalence and Evolution Trend of Orthopedic Surgeries in Romania

Flaviu Moldovan et al.

Summary: This study analyzes the annual volumes of orthopedic surgeries in Romania from 2001 to 2022 using data from the National Endoprosthetic Registry. The results show increasing trends in surgical interventions and highlight the anticipated need for more medical personnel and material resources.

HEALTHCARE (2023)

Article Surgery

THE USE OF TECHNOLOGY TO ACHIEVE THE FUNCTIONAL ACETABULAR SAFE ZONE IN TOTAL HIP ARTHROPLASTY

Eric N. Windsor et al.

Summary: Functional acetabular safe zones based on patient-specific factors during total hip arthroplasty are believed to improve component stability compared to traditional safe zones. Preoperative planning should consider functional pelvic positions and spinopelvic mobility. Computer navigation and robotics can be used to accurately achieve the targeted cup position within the functional safe zone.

JBJS REVIEWS (2022)

Article Orthopedics

Impaction Grafting Is Sufficient to Address Acetabular Deficiency During Total Hip Arthroplasty of Most Dysplastic Hips With Over 30% Bone Defect

Javad Khaje Mozafari et al.

Summary: This study assessed the outcomes of using impaction or structural graft to address acetabular deficiency during arthroplasty of dysplastic hips. The results showed that majority of the patients with over 30% defect can be treated with a cementless cup and impaction grafting, with good midterm results. In about 20% of cases, a structural support-like shelf graft is required.

JOURNAL OF ARTHROPLASTY (2022)

Review Medicine, General & Internal

Efficacy and Safety of Acetabular Cup without Screw Fixation in Total Hip Arthroplasty: A Systematic Review and Meta-Analysis

Takanori Miura et al.

Summary: There is currently no consensus on the use of screw fixation in total hip arthroplasty for acetabular cups. This study found that using acetabular cups without screw fixation had little to no effect on reoperation, cup migration, and Harris Hip Score. Further large-scale studies with low risk of bias are needed to confirm these findings.

MEDICINA-LITHUANIA (2022)

Article Orthopedics

Does Cup Position at the High Hip Center or Anatomic Hip Center in THA for Developmental Dysplasia of the Hip Result in Better Harris Hip Scores and Revision Incidence? A Systematic Review

Patrick Stirling et al.

Summary: There is no clear consensus on whether placing the acetabular cup in the high hip center or the anatomic hip center provides better outcomes or long-term survival in patients undergoing THA for developmental dysplasia of the hip. Both cup positions have their own advantages and disadvantages, and surgeons should consider factors such as surgical complexity, complications, and hip biomechanics when making a choice. Researchers should address limitations in future studies, such as confounding factors, inconsistent definitions, variations in disease severity, small sample sizes, and follow-up periods.

CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2021)

Article Orthopedics

Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans

Tarun Goyal et al.

Summary: The study found a strong correlation between acetabular component version measured on plain radiographs and on CT scans. Good correlations were observed between different techniques of measurement on radiographs, indicating that these methods can be valid for assessing anteversion.

CLINICS IN ORTHOPEDIC SURGERY (2021)

Article Orthopedics

Comparison of Cup Setting Angle Accuracy between Computed Tomography-Based and Computed Tomography-Free Navigation in the Same Patients with Crowe's Classification I or II Hip Dysplasia

Nobuhiro Kaku et al.

Summary: This study compared the accuracy of cup installation between computed tomography-based navigation and computed tomography-free navigation, and found that the former is more accurate. When using computed tomography-free navigation, additional technical schemes are needed before and during surgery to improve cup installation accuracy.

CLINICS IN ORTHOPEDIC SURGERY (2021)

Article Orthopedics

Hybrid total hip arthroplasty for multiple epiphyseal dysplasia

J. Vanlommel et al.

ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH (2018)

Article Orthopedics

Challenges in Total Hip Arthroplasty in the Setting of Developmental Dysplasia of the Hip

Eric M. Greber et al.

JOURNAL OF ARTHROPLASTY (2017)

Article Biotechnology & Applied Microbiology

Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

Masanori Fujii et al.

BIOMED RESEARCH INTERNATIONAL (2017)

Article

Initial stability of cementless acetabular cups: press-fit and screw fixation interaction—an in vitro biomechanical study

Tomonori Tabata et al.

European Journal of Orthopaedic Surgery and Traumatology (2014)

Article Orthopedics

Is Cup Positioning Challenged in Hips Previously Treated With Periacetabular Osteotomy?

Charlotte Hartig-Andreasen et al.

JOURNAL OF ARTHROPLASTY (2014)

Review Orthopedics

Total Hip Arthroplasty for Adult Hip Dysplasia

Benedict A. Rogers et al.

JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME (2012)

Article Orthopedics

The Results of a Press-Fit-Only Technique for Acetabular Fixation in Hip Dysplasia

Masaki Takao et al.

JOURNAL OF ARTHROPLASTY (2011)

Article Orthopedics

Polyethylene wear and acetabular component orientation

S Patil et al.

JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME (2003)