4.6 Article

Rapid Surface Modification of Stainless Steel 304L Electrodes for Microbial Electrochemical Sensor Application

期刊

ACS BIOMATERIALS SCIENCE & ENGINEERING
卷 9, 期 11, 页码 6034-6044

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsbiomaterials.3c00453

关键词

material development; surface modification; stainless steel 304L; carbon coating; flame oxidization; microbial electrochemical sensor; biosensor

向作者/读者索取更多资源

This study demonstrates low-cost and rapid surface modification strategies for microbial electrochemical sensors, which successfully detect multiple pollutants. The carbon powder-coated bioanode shows the best signal profile and roughness, indicating its potential to replace conventional water quality analysis methods.
Electrogenic microorganisms serve as important biocatalysts for microbial electrochemical sensors (MESes). The electrical signal produced is based on the rate of electron transfer between the microbes and electrodes, which represents the biotoxicity of water. However, existing MESes require complex and sophisticated fabrication methods. Here, several low-cost and rapid surface modification strategies (carbon powder-coated, flame-oxidized, and acid-bleached) have been demonstrated and studied for biosensing purposes. Surface-modified MESe bioanodes were successfully applied to detect multiple model pollutants including sodium acetate, ethanol, thinner, and palm oil mill effluent under three different testing sequences, namely, pollutant incremental, pollutant dumping, and water dilution tests. The carbon powder-coated bioanode showed the most responsive signal profile for all the three tests, which is in line with the average roughness values (R-a) when tested with atomic force microscopy. The carbon powder-coated electrode possessed a R-a value of 0.844, while flame-oxidized, acid-bleached, and control samples recorded 0.323, 0.336, and 0.264, respectively. The higher roughness was caused by the carbon coating and provided adhesive sites for microbial attachment and growth. The accuracy of MESe was also verified by correlating with chemical oxygen demand (COD) results. Similar to the sensitivity test, the carbon powder-coated bioanode obtained the highest R-2 value of 0.9754 when correlated with COD results, indicating a high potential of replacing conventional water quality analysis methods. The reported work is of great significance to showcase facile surface modification techniques for MESes, which are cost-effective and sustainable while retaining the biocompatibility toward the microbial community with carbon-based coatings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据