4.7 Article

Design and Analysis of Universal Natural Fault-Tolerant SVPWM Strategy With Simplified Fault Diagnosis for Multiphase Motor Drives

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JESTPE.2023.3270428

关键词

Fault-tolerant strategy; multiphase motors; open-phase fault; space vector pulsewidth modulation (SVPWM)

向作者/读者索取更多资源

Conventional space vector pulsewidth modulation (SVPWM) degrades performance of multiphase motor drives under open-phase fault. Existing solutions require reconfiguration of transformation matrices, making industrial implementation difficult. This study proposes a fault-tolerant SVPWM strategy that offers natural fault tolerance, simplified fault detection, minimum reconfiguration, torque ripple-free operation, and applicability to various open-phase faults using a single-transformation matrix. The proposed approach eliminates redundant controllers and reduces difficulty of fault diagnosis. Experimental evaluation demonstrates that torque ripple can be reduced by approximately 40% compared to conventional SVPWM strategy in the presence of multiple faults.
Conventional space vector pulsewidth modulation (SVPWM) would degrade the operating performance of the multiphase motor drives under open-phase fault. To resolve this issue, existing solutions require the reconfiguration of transformation matrices. However, for the variable positions of faulty phases, the structure of matrices needs to be redefined, which is a restraint to the industrial implementation of such technologies. This study examined the offset of the voltage vectors after fault occurrence. Accordingly, a universal fault-tolerant SVPWM strategy is proposed for the purpose of natural fault tolerance, as well as a simplified fault detection scheme. Compared with conventional fault-tolerant SVPWM, it is highlighted with the characteristics of minimum reconfiguration, torque ripple-free operation, and applicability to handle various types of open-phase faults using a single-transformation matrix. Besides, the proposed strategy eliminates the redundant controllers and also reduces the degree of difficulty for fault diagnosis. Finally, the effectiveness of the proposed approach is evaluated experimentally with a seven-phase induction machine, which shows that the torque ripple could be reduced by about 40% in the presence of multiple faults compared with the conventional SVPWM strategy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据