4.6 Article

Evaluation of Preferences for a Thermal-Camera-Based Abnormal Situation Detection Service via the Integrated Fuzzy AHP/TOPSIS Model

期刊

APPLIED SCIENCES-BASEL
卷 13, 期 20, 页码 -

出版社

MDPI
DOI: 10.3390/app132011591

关键词

abnormal situation detection service; thermal camera; integrated fuzzy AHP/TOPSIS model; preference evaluation; AHP; TOPSIS

向作者/读者索取更多资源

This study presents a thermal camera-based abnormal-situation detection service and proposes an integrated Fuzzy AHP/TOPSIS model to support the decision-making process of introducing thermography cameras. The findings show that developers highly value services that can detect temperature changes to identify early signs of dangerous situations, while local governments prioritize control services related to citizen safety.
Research related to thermal cameras, which are major control measures, is increasing to overcome the limitations of closed-circuit television (CCTV) images. Thermal cameras have the advantage of easily detecting objects at night and of being able to identify initial signs of dangerous situations owing to changes in temperature. However, research on thermal cameras from a comprehensive perspective for practical urban control is insufficient. Accordingly, this study presents a thermal camera-based abnormal-situation detection service that can supplement/replace CCTV image analysis and evaluate service preferences. We suggested an integrated Fuzzy AHP/TOPSIS model, which induces a more reasonable selection to support the decision-making of the demand for introducing thermography cameras. We found that developers highly evaluated services that can identify early signs of dangerous situations by detecting temperature changes in heat, which is the core principle of thermography cameras (e.g., pre-fire phenomenon), while local governments highly evaluated control services related to citizen safety (e.g., pedestrian detection at night). Clearly, while selecting an effective service model, the opinions of experts with a high understanding of the technology itself and operators who actually manage ser-vices should be appropriately reflected. This study contributes to the literature and provides the basic foundation for the development of services utilizing thermography cameras by presenting a thermography camera-based abnormal situation detection service and selection methods and joint decision-making engagement between developers and operators.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据