4.6 Article

Preparation of Reactive Indicator Papers Based on Silver-Containing Nanocomposites for the Analysis of Chloride Ions

期刊

MICROMACHINES
卷 14, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/mi14091682

关键词

nanocomposites; metal-containing monomers; reactive indicator paper; chloride ions; analysis

向作者/读者索取更多资源

Metal-containing nanocomposites have attracted attention in recent years. This study focused on the preparation and application of silver-containing nanocomposites derived from silver fumarate for reactive indicator papers (RIPs). The study explored the optical properties of the nanocomposites and developed a method for determining chloride ions using the color change of RIPs interacting with chlorine vapor. The technique showed promising results in the analysis of natural waters, pharmaceuticals, and food products.
In recent decades, metal-containing nanocomposites have attracted considerable attention from researchers. In this work, for the first time, a detailed analysis of the preparation of reactive indicator papers (RIPs) based on silver-containing nanocomposites derived from silver fumarate was carried out. Thermolysis products are silver-containing nanocomposites containing silver nanoparticles uniformly distributed in a stabilizing carbon matrix. The study of the optical properties of silver-containing nanocomposites made it possible to outline the prospects for their application in chemical analysis. RIPs were made by impregnating a cellulose carrier with synthesized silver fumarate-derived nanocomposites, which change their color when interacting with chlorine vapor. This made it possible to propose a method for the determination of chloride ions with preliminary oxidation to molecular chlorine, which is then separated from the solution by gas extraction. The subsequent detection of the active zone of RIPs using colorimetry makes it possible to identify mathematical dependences of color coordinates on the concentration of chloride ions. The red (R) color coordinate in the RGB (red-green-blue) system was chosen as the most sensitive and promising analytical signal. Calibration plots of exponential and linear form and their equations are presented. The limit of detection is 0.036 mg/L, the limits of quantification are 0.15-2.4 mg/L, and the time of a single determination is 25 min. The prospects of the developed technique have been successfully shown in the example of the analysis of the natural waters of the Don River, pharmaceuticals, and food products.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据