4.6 Article

Evaluation of Drinking Water Quality and Treatment from Coolers in Public Places in Madinah City, Saudi Arabia

期刊

WATER
卷 15, 期 14, 页码 -

出版社

MDPI
DOI: 10.3390/w15142565

关键词

quality evaluation; public water coolers; public health; standards of drinking water; water desalination methods; desalination techniques

向作者/读者索取更多资源

The aim of this study is to prevent public drinking from water coolers with low-quality water by using an auto-detection process. The proposed water treatment management system allows dispensers to provide the best-quality water. The study investigates the quality of drinking water from coolers in public places in Madinah and recommends regular maintenance and optimal design for the water desalination process to ensure clean and safe drinking water.
The aim of this work is to prevent the public drinking from water coolers, by using an auto-detection process, if the quality of water is low. Therefore, the proposed water treatment management system for allows the activation of dispensers to provide the best-quality water coolers. The objective is to investigate the quality of the drinking water from coolers in public places in Madinah and to provide clean, safe, and healthy drinking water for the general public. The methodology consisted of performing different analyses, tests, and water treatments, such as physicochemical analyses of the water samples, measurements of the different concentrations of anions, measurements of the concentrations of heavy metals, and bacteriological tests of the water samples. Therefore, 66 water samples were tested, and the experimental values were compared with the reference values given by the World Health Organization (WHO) and Saudi Standards, Metrology, and Quality Organization (SASO) for drinking water. The tests revealed that the physicochemical parameters (pH, EC, TDS, and TH) of different water sources (95.5%) were in accordance with the SASO and WHO values. In addition, all the analyzed water samples (100%) contained permissible levels of nitrates, sulfates, nitrites, and free residual chlorine, as indicated by the results. However, 68.2% of the samples studied had fluoride concentrations below the standard limits. Furthermore, heavy metals such as lead, iron, and others were tested for all water coolers. The measured findings indicated that just one cooler exceeded the permissible limit of 0.3 mg/L for Fe, and the biological contamination testing revealed that 4.5% of the coolers were infected with coliforms. Finally, this research suggests that water coolers should be regularly maintained. Additionally, using the best design for the water desalination process is very important to give the best drinking water quality.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据