4.5 Article

Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study

期刊

BMC ORAL HEALTH
卷 23, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12903-023-03297-0

关键词

Computer-assisted implant surgery (CAIS); Dental implant; Surgical guide; Static navigation; Implant drill; Step drill; Straight drill; In vitro study

向作者/读者索取更多资源

The accuracy of implant placement in model surgeries was compared according to the design of the drills used. Using step drills instead of straight drills for final osteotomies decreased deviation from the surgical plan, and the fully guided approach performed better than the pilot-guided sCAIS.
BackgroundThe purpose of this in vitro study was to compare the accuracy of implant placement in model surgeries according to the design of the drills (straight drills or step drills) used to finalize the implant bed during pilot-guided static computer-assisted implant surgery (sCAIS).MethodsModel surgeries were carried out on resin models randomly assigned to three study groups. Virtual planning software (coDiagnostiX 10.6, Dental Wings, Montreal, Canada) was used to plan the implant positions. In Groups 1 and 2, pilot-guided sCAIS was performed. Straight drills were used in Group 1, and step drills were used in Group 2 to finalize the implant beds. In Group 3, fully guided sCAIS was performed using a universal fully guided kit (RealGUIDE Full Surgical Kit 3DIEMME, RealGUIDE, Cantu, Como, Italy). A total of 90 dental implants (Callus Pro, Callus Implant Solutions GmbH, Nuremberg, Germany) were placed (six implants per model, five models per study group). The primary outcome variables (angular deviation, coronal global deviation, and apical global deviation) were calculated for all implants based on the comparison of the preoperative surgical plan with the postoperative scans.ResultsGroup 2 (coronal global deviation, 0.78 & PLUSMN; 0.29 mm; apical global deviation, 1.02 & PLUSMN; 0.56 mm) showed significantly lower values of both global deviation variables than Group 1 (coronal global deviation, 0.95 & PLUSMN; 0.20 mm; apical global deviation, 1.42 & PLUSMN; 0.49 mm). However, there was no significant difference in angular deviation between Groups 1 and 2 (7.56 & PLUSMN; 2.92 & DEG; and 6.44 & PLUSMN; 2.84 & DEG;). Group 3 produced significantly lower values of all three primary outcome variables (angular deviation, 2.36 & PLUSMN; 0.90 & DEG;; coronal global deviation, 0.59 & PLUSMN; 0.28 mm; apical global deviation, 0.90 & PLUSMN; 0.29 mm) than Group 1 and significantly lower angular deviation and coronal global deviation values than Group 2.ConclusionsThe design of the drills used to finalize implant osteotomies during pilot-guided sCAIS influences dental implant placement accuracy. Using step drills instead of straight drills for final osteotomies decreases deviation from the surgical plan. The fully guided approach performed better than the pilot-guided sCAIS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据