This study investigates the impact of ventilation conditions and stove locations on air quality and thermal comfort in a kitchen where fish is fried using African cooking styles with palm oil. The results show that bleaching and frying increase the concentrations of pollutants, temperature, and carbon monoxide, while reducing relative humidity. Opening windows and doors and placing the stove near the window can improve indoor temperature and air quality by reducing pollutant concentrations, while increasing humidity. Bleaching and frying with palm oil are found to be harmful to human health and thermal comfort.
This paper documented the effect of ventilation conditions and stove locations on air quality and thermal comfort in a kitchen where fish was fried via African cooking styles using palm oil. CO, CO2, PM2.5, PM10, HCHO, TVOC, relative humidity (RH), and temperature were measured using an air quality detector. The position of the kerosene stove (at the window and adjacent wall) and conditions of the door and windows (fully and partly open) were altered to study their effect. Data of the pollutants concentrations and thermal comfort parameters were acquired and analyzed for the background, bleaching, frying, and after-frying durations for the different cases of stove locations and door and windows conditions. Bleaching and frying were noticed to increase the background PM2.5, PM10, CO2, HCHO, TVOC, temperature, and CO by 604-1301 mu g/m(3), 729-2760 mu g/m(3), 78-266 ppm, 0.03-0.13 mg/m(3), 0.04-0.16 mg/m(3), 0.83-8.33 C-? and 18-189 ppm, respectively and reduced RH by 1.67-13.33%, for all the studied test conditions. PM10 followed by PM2.5 exhibited the slowest concentration decay. Opening the windows and door and placing the stove at the window area were observed to lower the indoor temperature, PM2.5, PM10, CO2, and CO concentrations, and heat index of the studied environment as the RH, HCHO, and TVOC were increased. Bleaching + frying using palm oil is found to be injurious to human health and thermal comfort (as heat index >32) and should be carried out with serious safety precautions as provided herein.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据