4.7 Article

Green turn-off luminescent nanosensors for the sensitive determination of desperately fluorescent antibacterial antiviral agent and its metabolite in various matrices

期刊

SCIENTIFIC REPORTS
卷 13, 期 1, 页码 -

出版社

NATURE PORTFOLIO
DOI: 10.1038/s41598-023-40946-4

关键词

-

向作者/读者索取更多资源

A highly sensitive and green spectrofluorometric method was developed for the detection of NTX and its metabolite, TX, and successfully applied to commercial formulations. This method exhibited superior sensitivity and allowed for the selective determination of TX in human plasma samples.
Nitazoxanide (NTX) is an antimicrobial drug that was used for the treatment of various protozoa. However, during the coronavirus pandemic, NTX has been redirected for the treatment of such virus that primarily infect the respiratory tract system. NTX is now used as a broad-spectrum antiviral agent. In this study, a highly sensitive and green spectrofluorometric method was developed to detect NTX in various dosage forms and its metabolite, tizoxanide (TX), in human plasma samples using nitrogen and sulfur co-doped carbon quantum dots nanosensors (C-dots). A simple and eco-friendly hydrothermal method was used to synthetize water soluble C-dots from citric acid and l-cysteine. After excitation at 345 nm, the luminescence intensity was measured at 416 nm. Quenching of C-dots luminescence occurred upon the addition of NTX and was proportional to NTX concentration. Assessment of the quenching mechanism was performed to prove that inner filter effect is the underlying molecular mechanism of NTX quenching accomplished. After optimizing all experimental parameters, the analytical procedure was evaluated and validated using the ICH guidelines. The method linearity, detection and quantification limits of NTX were 15 x 10(-3) -15.00 mu g/mL, 56.00 x10(-4) and 15 x 10- 3 mu g/mL, respectively. The proposed method was applied for the determination of NTX in its commercial pharmaceutical products; Nanazoxid (R) oral suspension and tablets. The obtained % recovery, relative standard deviation and % relative error were satisfactory. Comparison with other reported spectrofluorimetric methods revealed the superior sensitivity of the proposed method. Such high sensitivity permitted the selective determination of TX, the main metabolite of NTX, in human plasma samples making this study the first spectrofluorimetric method in literature that determine TX in human plasma samples. Moreover, the method greenness was assessed using both Eco-Scale and AGREE approaches to prove the superiority of the proposed method greenness over other previously published spectrofluorimetric methods for the analysis of NTX and its metabolite, TX, in various dosage forms and in human plasma samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据