4.6 Article

Elucidating the Mass Transportation Behavior of Gas Diffusion Layers via a H-2 Limiting Current Test

期刊

MATERIALS
卷 16, 期 16, 页码 -

出版社

MDPI
DOI: 10.3390/ma16165670

关键词

proton exchange membrane fuel cells; gas diffusion layer; mass transport resistance; limiting current; hydrogen probe

向作者/读者索取更多资源

To investigate the correlation between GDL structure and mass transport properties, a limiting current test was conducted on three representative GDLs with and without the microporous layer. The results showed that the transport resistance of GDLs was affected by the thickness and pore size distribution of the macroporous substrate and the MPL.
The gas diffusion layer (GDL), as a key component of proton exchange membrane fuel cells (PEMFCs), plays a crucial role in PEMFC's polarization performance, particularly in mass transport properties at high current densities. To elucidate the correlation between GDLs' structure and their mass transport properties, a limiting current test with the H2 molecular probe was established and employed to investigate three representative GDLs with and without the microporous layer (MPL). By varying humidity and back pressure, the mass transport resistance of three GDLs was measured in an operating fuel cell, and an elaborate analysis of H-2 transport was conducted. The results showed that the transport resistance (R-DM) of GDLs was affected by the thickness and pore size distribution of the macroporous substrate (MPS) and the MPL. In the process of gas transport, the smaller pore size and thicker MPL increase the force of gas on the pore wall, resulting in an increase in transmission resistance. Through further calculation and analysis, the total transport resistance can be divided into pressure-related resistance (R-P) and pressure-independent resistance (R-NP). R-P mainly originates from the transport resistance in both MPLs and the substrate layers of GDLs, exhibiting a linear relationship to the pressure; R(NP )mainly originates from the transport resistance in the MPLs. 29BC with thick MPL shows the largest R-NP, and T060 without MPL shows the R-NP = 0. This methodology enables in situ measurements of mass transport resistances for gas diffusion media, which can be easily applied for developing and deploying PEMFCs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据