4.1 Article

Microfluidic Platform for Microparticle Fabrication and Release of a Cathepsin Inhibitor

期刊

TISSUE ENGINEERING PART C-METHODS
卷 29, 期 8, 页码 361-370

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/ten.tec.2023.0015

关键词

microparticle; poly(ethylene glycol); microfluidic device; sustained release; cathepsin

向作者/读者索取更多资源

This study successfully developed a novel microfluidic device to fabricate uniform, hydrolytically degradable microparticles loaded with the cathepsin inhibitor E-64. Commercially available fluorogenic assays were validated to quantify the release and bioactivity of the inhibitor from the biomaterial carriers. These technologies make significant contributions towards local delivery of cathepsin inhibitors.
Impact statementLocal delivery of cathepsin inhibitors may reduce progression of a wide variety of diseases. This work provides two contributions toward this goal. First, a novel microfluidic device was used to fabricate uniform, hydrolytically degradable poly(ethylene glycol) diacrylate/dithiothreitol microparticles loaded with the cathepsin inhibitor E-64. Subsequently, commercially available fluorogenic assays were validated to simultaneously quantify release and bioactivity of the inhibitor from the biomaterial carriers. Cathepsins are a family of cysteine proteases responsible for a variety of homeostatic functions throughout the body, including extracellular matrix remodeling, and have been implicated in a variety of degenerative diseases. However, clinical trials using systemic administration of cathepsin inhibitors have been abandoned due to side effects, so local delivery of cathepsin inhibitors may be advantageous. In these experiments, a novel microfluidic device platform was developed that can synthesize uniform, hydrolytically degradable microparticles from a combination of poly(ethylene glycol) diacrylate (PEGDA) and dithiothreitol (DTT). Of the formulations examined, the 10-polymer weight percentage 10 mM DTT formulation degraded after 77 days in vitro. A modified assay using the DQ Gelatin Fluorogenic Substrate was used to demonstrate sustained release and bioactivity of a cathepsin inhibitor (E-64) released from hydrogel microparticles over 2 weeks in vitro (up to & SIM;13 & mu;g/mL released with up to & SIM;40% original level of inhibition remaining at day 14). Altogether, the technologies developed in this study will allow a small-molecule, broad cathepsin inhibitor E-64 to be released in a sustained manner for localized inhibition of cathepsins for a wide variety of diseases.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据