4.6 Article

Transient analysis and techno-economic assessment of thermal energy storage integrated with solar air heater for energy management in drying

期刊

SOLAR ENERGY
卷 264, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2023.112043

关键词

Thermal energy storage; Drying; Charging; Discharging; Energy stored; Energy recovered

向作者/读者索取更多资源

This pioneering research developed a transient thermodynamic model and conducted an economic analysis of the integration of a conical shaped rock bed thermal energy storage (TES) system with a solar air heater. The results showed high energy storage and recovery capabilities of the optimized TES system, and the hybrid application demonstrated a remarkable reduction in energy payback period, indicating its superior economic value.
The integration of thermal energy storage (TES) system with solar air heater holds an immense potential for optimising the energy management in drying application. In this pioneer research, a transient thermodynamic model of conical shaped rock bed TES has been developed, and the economic analysis of hybrid V-groove double pass solar air heater (SAH)-TES has been studied, offering a unique perspective on the feasibility and economic viability of hybrid SAH-TES for drying application. By considering the time dependent dynamics of energy demand, the model predicts energy stored and released by the system during charging and discharging with a considerable error of 9.9%, as validated with a pilot scale experimental setup. The numerical and experimental results showed that the stored and recovered energy is highly dependent on the inlet temperature and flow rate of air. Notably, the optimised conical shaped TES has the capacity of storing 15.6 kWh of energy during six-hour charging period enabling the recovery of 33% of the stored energy to power the dryer during the discharge period. Moreover, the pressure drop across the TES observed to be 1306.37 Pa/m at 0.050 kg/s, which quantify the power required for fan to overcome such pressure drop to be 4.22 kW Furthermore, the economic assessment showcased remarkable reduction in energy payback period, dropping from 0.7 years to 0.5 years using hybrid SAH-TES dryer compared to SAH dryer. This demonstrates the superior economic value of the hybrid SAH-TES dryer paving the way for the scalability and widespread adoption of low-carbon drying industry.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据