4.6 Article

Multi-criteria evaluation of daylight control systems of office buildings considering daylighting, glare and energy consumption

期刊

SOLAR ENERGY
卷 263, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2023.111928

关键词

Daylight control systems; Multi-criteria decision-making; Daylight; Energy efficiency; Visual comfort

向作者/读者索取更多资源

Daylight control systems (DCSs) are formed by coupling glazing and shading systems to enhance visual comfort and energy efficiency in buildings. However, there is an inherent contradiction in the design of DCSs, as daylight can simultaneously affect energy efficiency and glare. A study evaluating 155 DCSs using multi-criteria decision-making (MCDM) method found that coupling reflected horizontal louvers with vacuum glazing is the most effective design alternative regardless of orientation, with south-facing buildings being the optimal choice for achieving daylighting, glare reduction, and energy efficiency simultaneously.
Through the coupling of glazing and shading systems, daylight control systems (DCSs) are formed. By using such systems, the visual comfort of occupants as well as the energy efficiency of the building can be greatly enhanced. Further, these systems are imperative in climates where excessive and uncontrolled daylight may result in sig-nificant increases in cooling loads and glare, as well as a decrease in visual efficiency. There is, however, an inherent contradiction in the design of DCSs. This is due to the way daylight affects indoor spaces in that, despite being beneficial for visual comfort, it can also be detrimental to energy efficiency and glare, or vice versa. Therefore, to achieve a near-optimal indoor environment, daylighting should be increased while glare and en-ergy consumption should be reduced. In this study, 155 unique DCSs are evaluated in cardinal and intercardinal orientations using a multi-criteria decision-making (MCDM) method. For each design alternative, daylighting, glare, and energy simulations are conducted using UDI, sGA, and EUI as performance metrics. The MCDM method, then, ranks the utility of the DCSs by aggregating the weighted simulations results. Results indicate that the coupling of reflected horizontal louvers with vacuum glazing is the most frequently used best design alternative regardless of orientation. Further, it is revealed that among all the top-ranked DCSs in each orien-tation, those in the south orientation are found to be the most effective at improving daylighting, glare, and energy efficiency simultaneously. It is also found that when an architectural design is intended to achieve daylighting, glare reduction, and energy efficiency simultaneously, a south-facing building is the optimal choice.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据