4.7 Article

Flexible humidity sensor based on crosslinked polyethyleneimine/tannic acid and porous carbonaceous interdigitated electrode

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 393, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2023.134194

关键词

Polyethyleneimine; Tannic acid; Crosslinking; Humidity sensor; Porous interdigitated electrode; Direct laser writing carbonization

向作者/读者索取更多资源

Polymers and polymer composites are ideal for wearable and flexible humidity sensors due to their flexibility, low cost, and ease of processing. However, their long-term stability is a concern. In this study, chemically crosslinked TA-x-PEI based humidity sensors were fabricated through a simple spray coating process using the robust Michael addition reaction between PEI and TA. The combination of TA-x-PEI with PC-IDE allowed for the fabrication of high-performance flexible humidity sensors with fast response and recovery, low hysteresis, good long-term stability, and high sensitivity.
For their advantages of flexibility in nature, low cost, and ease of processing, polymers and polymer composites are considered to be ideal candidates for the development of wearable and flexible humidity sensors. Nevertheless, the commonly adopted polymer-based humidity sensing materials are usually subjected to long-term stability issue, due to a lack of chemically crosslinked network structure. Herein, we rely on the robust Michael addition reaction between polyethyleneimine (PEI) and tannic acid (TA) in aqueous solution for fabricating the chemically crosslinked TA-x-PEI based humidity sensors through a simple spray coating process. With assistance of direct laser writing carbonization (DLWc) technique, we demonstrate that the combination of TA-x-PEI with porous carbon interdigitated electrode (PC-IDE) allows for facile fabrication of high-performance flexible humidity sensors, which possess fast response and recovery performance (28 s/12 s), low hysteresis (2%) in the range of 35% RH -90% RH, good long-term stability (impedance change < 2% over 30 days) and high sensitivity, as demonstrated by a comparison of key metrics with similar humidity sensors reported in the literature. SEM microscopy, Raman and FTIR spectroscopy, frequency-dependent impedance measurement, as well as equivalent circuit modeling have been performed to gain an in-depth understanding of the humidity sensing behavior and the underlying mechanism for the newly developed PC-IDE enabled TA-x-PEI based humidity sensors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据